Features:
Provides radiant heat support for newborns during examination, resuscitation, or procedures
Designed for integration with separate bassinets or treatment tables
Overhead radiant heating element delivers consistent warmth to the infant
Servo-controlled temperature regulation with skin probe for precision
Digital display shows skin temperature, heater output, and system status
Alarm system for high/low temperature, sensor failure, and power issues
Height-adjustable heater head for focused thermal management
Compact, open design allows unobstructed access from all sides
Wall-mountable or mobile stand options depending on setup
Specifications:
Heating source: Quartz or ceramic radiant heater
Temperature control: Servo and manual modes
Skin temperature range: 34°C to 39°C (adjustable)
Display: LED or LCD for temperature and alarms
Power supply: 220–240 V, 50/60 Hz
Heater tilt adjustment: ~0° to 90° (manual)
Safety: Audio-visual alarms, automatic cutoff, thermal fuse
Frame: Epoxy-coated or stainless steel structure
Measurement Method: Manual
Measurement Range: 0 – 300 mmHg
Accuracy: ±2 mmHg
Graduation: 2 mmHg increments
Cuff Size: 22 – 42 cm
Bladder Material: Latex or PVC, 2-tube system
Bulb Type: Rubber inflation bulb with chrome-plated release valve
Valve Type: Precision screw-type air control
Mercury Column: Glass tube with metal scale backing
Stand Type: Height-adjustable pole with 5-leg wheeled base
Tubing: Extendable tubing
Unit Height: Adjustable from 900 mm to 1300 mm
Weight: 4.5 – 6 kg
Operating Temperature: 10°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Method: Manual
Measurement Range: 0 – 300 mmHg
Accuracy: ±2 mmHg
Graduation: 2 mmHg increments
Cuff Size: 22 – 42 cm
Bladder Material: Latex or PVC, 2-tube design
Bulb: Rubber inflation bulb with air-release valve
Valve Type: Chrome-plated screw-type
Mercury Column: Glass tube with metal scale backing
Base Material: Powder-coated metal or ABS plastic
Weight: 2.5 – 3 kg
Operating Temperature: 10°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Method: Manual (Aneroid, Auscultatory)
Measurement Range: 0 – 300 mmHg
Accuracy: ±3 mmHg
Cuff Size Range: 22 – 42 cm
Dial Diameter: 50 mm
Manometer Type: Aneroid with 2 mmHg graduation
Bladder Material: Latex or PVC, 2-tube design
Bulb: Rubber inflation bulb with chrome-plated valve
Valve Type: Screw-type precision air release
Stethoscope: Optional, single-head compatible
Weight: 500 g
Operating Temperature: 5°C – 40°C
Storage Temperature: -10°C – 50°C
Technical Specifications
©2025-26. All Rights Reserved. Shresha Biortek