Features:
Foldable design for easy storage and portability
Cushioned top with high-density foam for patient comfort
Upholstered with durable, water-resistant synthetic material
Backrest adjustable for varied examination needs
Sturdy, foldable frame ensures stability and quick setup
Lightweight and compact, ideal for mobile clinics and space-constrained facilities
Smooth edges and reinforced joints for safety and longevity
Available with both anti-skid rubber shoes and smooth-rolling castors with brakes for mobility and secure placement
Specifications:
Frame material: Mild steel or stainless steel with epoxy powder coating
Upholstery: Synthetic leather or rexine, easy to clean and disinfect
Mattress thickness: Approx. 50–75 mm
Overall dimensions (open): Approx. 1800 x 500–600 x 800 mm
Folded dimensions: Approx. 900 x 500–600 x 250 mm
Backrest adjustment: Manually adjustable up to approx. 70°
Base: Anti-skid rubber shoes and/or lockable smooth-rolling castors
Load capacity: Up to 120–150 kg
Finish: Epoxy powder coated or polished stainless steel
Weight: Approx. 25–40 kg
Height Adjustment Range (Hi-Lo): 450 mm – 750 mm
Backrest Angle: 0° – 75° (manual crank)
Knee Rest Angle: 0° – 35° (manual crank)
Trendelenburg: 0° – 12° (manual)
Reverse Trendelenburg: 0° – 12° (manual)
Platform Sections: 4-section perforated MS platform
Frame Material: CRCA steel with epoxy powder coating
Head & Foot Panels: ABS, detachable
Side Rails: Collapsible, aluminum or ABS
Crank System: 3 separate crank handles (backrest, knee rest, Hi-Lo)
Safe Working Load: 200 – 250 kg
Measurement Method: Manual (Aneroid, Auscultatory)
Measurement Range: 0 – 300 mmHg
Accuracy: ±3 mmHg
Cuff Size Range: 22 – 42 cm
Dial Diameter: 50 mm
Manometer Type: Aneroid with 2 mmHg graduation
Bladder Material: Latex or PVC, 2-tube design
Bulb: Rubber inflation bulb with chrome-plated valve
Valve Type: Screw-type precision air release
Stethoscope: Optional, single-head compatible
Weight: 500 g
Operating Temperature: 5°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Method: Oscillometric
Measurement Range:
– Systolic: 60 – 260 mmHg
– Diastolic: 40 – 199 mmHg
– Pulse Rate: 40 – 180 bpm
Measurement Accuracy:
– Pressure: ±3 mmHg
– Pulse: ±5%
Display Type: LCD/LED digital screen
Memory Capacity: 60 – 120 readings per user
Power Supply:Â batteries or AC adapter
Cuff Size: 22 – 42 cm
Auto Power Off: After 1 minute of inactivity
Weight: 300 – 400 g
Operating Temperature: 5°C – 40°C
Humidity Range: 15% – 85% RH non-condensing
©2025-26. All Rights Reserved. Shresha Biortek