Features:
Hydraulic height adjustment for easy patient positioning and caregiver convenience
Three-section cushioned top for labor, delivery, and recovery stages
Removable foot-end section for unobstructed access during delivery
Adjustable backrest and leg section for multiple birthing positions
Lithotomy leg supports with padded stirrups and adjustable positioning
Hand-operated hydraulic mechanism ensures smooth and safe lifting
Comfortable, high-density foam mattress with water-resistant upholstery
Side safety rails for patient protection
Provision for IV rod, drainage tray, and other accessories
Fitted with both anti-skid rubber shoes and lockable smooth-rolling castors for mobility and stability
Ideal for labor and delivery rooms in hospitals and maternity clinics
Specifications:
Frame material: Heavy-duty mild steel or stainless steel with epoxy powder coating
Upholstery: Medical-grade synthetic leather or rexine, water- and stain-resistant
Mattress thickness: Approx. 75–100 mm
Overall dimensions: Approx. 1800–2000 x 600–700 mm
Height adjustment range: Approx. 600–900 mm (hydraulic lift)
Backrest adjustment: Up to approx. 70°
Leg section: Adjustable/detachable
Lithotomy poles: Adjustable with padded leg supports
Base: Anti-skid rubber shoes and/or lockable smooth-rolling castors
Load capacity: Up to 180 kg
Finish: Epoxy powder coated or polished stainless steel
Weight: Approx. 80–100 kg
Measurement Method: Manual (Aneroid, Auscultatory)
Measurement Range: 0 – 300 mmHg
Accuracy: ±3 mmHg
Cuff Size Range: 22 – 42 cm
Dial Diameter: 50 mm
Manometer Type: Aneroid with 2 mmHg graduation
Bladder Material: Latex or PVC, 2-tube design
Bulb: Rubber inflation bulb with chrome-plated valve
Valve Type: Screw-type precision air release
Stethoscope: Optional, single-head compatible
Weight: 500 g
Operating Temperature: 5°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Parameters:
– SpO₂ (Oxygen Saturation): 0% – 100%
– Pulse Rate: 30 – 250 bpm
SpO₂ Accuracy: ±2% (for 70% – 100% range)
Pulse Rate Accuracy: ±2 bpm or ±2%
Display Type: Large LED or TFT screen
Waveform Display: Plethysmograph (real-time pulse waveform)
Alarm Functions: Adjustable thresholds for SpOâ‚‚ and PR, with sound and visual indicators
Power Supply:
– AC mains (100 – 240V, 50/60 Hz)
– Built-in rechargeable battery
Battery Backup: 4 – 8 hours of operation
Data Storage: Up to 72 hours or more
Connectivity: USB / RS232 / LAN
Weight: ~1.5 – 3 kg
Operating Environment:
– Temperature: 5°C – 40°C
– Humidity: ≤85% non-condensing
Technical Specifications