Features:
Provides therapeutic blue light for treating neonatal jaundice
Positioned above the infant for effective single-surface phototherapy
Equipped with high-efficiency lamps (CFL or LED) emitting light in the optimal wavelength range
Adjustable height for proper light distance and treatment intensity
Transparent bassinet or cradle allows maximum light exposure
Integrated timer for tracking therapy duration
Low heat emission to prevent overheating and ensure infant comfort
Mounted on a mobile stand with locking casters for easy movement
Specifications:
Light source: CFL or LED (blue light, 420–480 nm)
Number of lamps: typically 4–6 CFL or an LED array
Irradiance: ≥ 30 µW/cm²/nm at recommended distance
Height adjustment range: ~100–150 mm
Power supply: 220–240 V, 50/60 Hz
Timer: Digital or analog (up to 99 hours)
Frame: Powder-coated or stainless steel stand
Cradle compatibility: Fits standard neonatal beds or bassinets
Height Adjustment Range (Hi-Lo): 450 mm – 750 mm
Backrest Angle: 0° – 75° (manual crank)
Knee Rest Angle: 0° – 35° (manual crank)
Trendelenburg: 0° – 12° (manual)
Reverse Trendelenburg: 0° – 12° (manual)
Platform Sections: 4-section perforated MS platform
Frame Material: CRCA steel with epoxy powder coating
Head & Foot Panels: ABS, detachable
Side Rails: Collapsible, aluminum or ABS
Crank System: 3 separate crank handles (backrest, knee rest, Hi-Lo)
Safe Working Load: 200 – 250 kg
Height Adjustment Range (Hi-Lo): 450 mm – 750 mm
Backrest Angle: 0° – 75° (manual crank)
Knee Rest Angle: 0° – 35° (manual crank)
Trendelenburg: 0° – 12° (manual)
Reverse Trendelenburg: 0° – 12° (manual)
Platform Sections: 4-section perforated MS platform
Frame Material:Â steel with epoxy powder coating
Head & Foot Panels: ABS, detachable
Side Rails: Collapsible, aluminum or ABS
Crank System: 3 separate crank handles (backrest, knee rest, Hi-Lo)
Safe Working Load: 200 – 250 kg
Measurement Method: Manual (Aneroid, Auscultatory)
Measurement Range: 0 – 300 mmHg
Accuracy: ±3 mmHg
Cuff Size Range: 22 – 42 cm
Dial Diameter: 50 mm
Manometer Type: Aneroid with 2 mmHg graduation
Bladder Material: Latex or PVC, 2-tube design
Bulb: Rubber inflation bulb with chrome-plated valve
Valve Type: Screw-type precision air release
Stethoscope: Optional, single-head compatible
Weight: 500 g
Operating Temperature: 5°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Method: Oscillometric
Measurement Range:
– Systolic: 60 – 260 mmHg
– Diastolic: 40 – 199 mmHg
– Pulse Rate: 40 – 180 bpm
Measurement Accuracy:
– Pressure: ±3 mmHg
– Pulse: ±5%
Display Type: LCD/LED digital screen
Memory Capacity: 60 – 120 readings per user
Power Supply:Â batteries or AC adapter
Cuff Size: 22 – 42 cm
Auto Power Off: After 1 minute of inactivity
Weight: 300 – 400 g
Operating Temperature: 5°C – 40°C
Humidity Range: 15% – 85% RH non-condensing