Hygienic & Contactless Operation
Operates via infrared sensors, eliminating the need for physical contact and reducing the risk of cross-contamination.
Automatic Water Dispensing
Water flows only when hands are detected, promoting water conservation and user convenience.
Sensor-Activated Faucets
Equipped with motion sensors (10–15 cm range) that activate water flow automatically.
Time-Controlled Shut-Off
Built-in timer (usually 30–60 seconds) ensures automatic shut-off to avoid water wastage.
Power Options
Operates on battery (DC 6V) or AC adapter, ensuring functionality during power variations.
Durable Construction
Made from ceramic, stainless steel, or composite materials that are corrosion-resistant and easy to clean.
Anti-Microbial Surfaces
Designed with smooth, germ-resistant surfaces suitable for high-risk hygiene areas like hospitals and labs.
Compliance & Standards
Often certified with CE, RoHS, or ISO standards to ensure quality, safety, and hygiene compliance.
| Sl no. | Type of Wash Basin | Model | Specification | Key Features | Description |
| 1 | Wall-Mounted Ceramic Basin | DR-WB-WM | Size: ~550×400×180 mm, IR sensor tap, ceramic body | Cost-effective, easy to install, auto shut-off sensor | Ideal for public restrooms, schools, and hospitals |
| 2 | Countertop Basin with Sensor | DR-WB-CB | Basin placed on counter, sensor faucet installed separately | Aesthetic design, durable finish, easy sensor access | Used in commercial offices, hotels, premium clinics |
| 3 | Integrated Sensor Basin Unit | DR-WB-IS | All-in-one basin with built-in tap, sensor, and soap dispenser | Compact design, plug & play, minimal plumbing | Suitable for high-end healthcare or corporate facilities |
| 4 | Stainless Steel Basin | DR-WB-SS | SS304/316 grade, vandal-proof sensor faucet, industrial finish | Durable, corrosion-resistant, sensor with battery/AC options | Best for industrial kitchens, labs, railway stations |
| 5 | Double/Triple Wash Station | DR-WB-DT | Multi-user basin with 2–3 sensors and taps integrated | Space-efficient, high-throughput, anti-drip sensor system | Suitable for operation theatres, ICUs, and high-traffic zones |
| 6 | Pediatric Sensor Basin | DR-WB-PD | Lower height, colorful design, gentle water flow sensor | Child-safe design, soft edges, temperature-controlled | Ideal for pediatric hospitals, schools, and child care centers |
| Type: Configuration | Model | Description | Typical Specifications | Key Features |
|---|---|---|---|---|
| Hermetically Sealed Sliding Door: Manual Single Leaf | DR H2SD MSL | Manually operated single-panel sliding door with hermetic seal for OTs and cleanrooms. | Size: 1200 x 2100 mm Leaf: Single Material: SS / HPL / Powder-coated GI Seal: Bottom + perimeter Opening: Manual push-pull |
– Smooth manual glide – Full hermetic sealing – Easy maintenance – Ideal for small OTs |
| Hermetically Sealed Sliding Door: Automatic Single-Leaf | DR H2SD ASL | Automated sliding door with sensor-based motion and full perimeter seal for infection control zones. | Drive: Microprocessor-controlled Size: 1200 x 2100 mm Opening Speed: 250–500 mm/sec Sensors: Infrared / microwave Power: 230V AC |
– Touchless operation – Hermetically sealed – Anti-crush safety – Silent motor |
| Hermetically Sealed Sliding Door: Automatic Double-Leaf | DR H2SD ADL | Wide-opening automatic dual-leaf sliding door for gurney and equipment movement. | Leaf Size: 2 x 1200 mm Total Opening: 2400 mm Material: SS304 / HPL Motor: Belt drive Sensors: Dual-zone presence sensor |
– Large clear opening – Double leaf automation – Medical-grade surface – Optional battery backup |
| Hermetically Sealed Sliding Door: Lead-Lined Radiation Proof | DR H2SD L2RF | Radiation-shielding sliding door for imaging/OT rooms with hermetic sealing. | Shielding: 2 mm Pb equivalence Leaf: SS/Lead/HPL composite Seal: 3-side hermetic Automation: Optional |
– X-ray/MRI compatible – Anti-radiation core – Smooth, quiet operation |
| Hermetically Sealed Sliding Door: Glass Panel with SS Frame | DR H2SD SPS | Transparent hermetic door with clear toughened glass for visibility between zones. | Glass: 10–12 mm toughened Frame: SS 304 Size: 1500 x 2100 mm Seal: Bottom drop seal Motor: Optional |
– Modern aesthetic – Visual access – Hermetic bottom seal – Cleanroom compliant |
| Hermetically Sealed Sliding Door: ICU/Isolation Room Bi-Parting | DR H2SD I2R2P | Bi-parting auto door system for ICU and isolation wards with negative pressure sealing. | Leaf Size: 2 x 1000 mm Motor: Low-noise linear motor Controls: Touchless switch Finish: Antibacterial HPL or SS |
– Suited for ICU/clean zones – Pressure integrity – Hands-free access |
| Hermetically Sealed Sliding Door: Fire Rated with Hermetic Seal | DR H2SD FRS | Sliding door certified for fire safety and hermetic sealing up to 60 minutes. | Fire Rating: EI60 Seal: Intumescent + hermetic Core: Rockwool + GI Automation: Available |
– Fire-resistant – Sealed for smoke/gas – Fire-rated glazing optional |
Access control (RFID, keypad, facial recognition)
Battery backup for motor
Touchless sensors and foot switches
Door status indicator lights (Red/Green)
Vision panels or X-ray safe glass
Cleanroom-rated antibacterial coatings
| Type | Model NO | Description | Specifications | Features |
|---|---|---|---|---|
| Standard IVF OT | DR ORIVF BMS | Entry-level OT for small to mid-sized IVF clinics. | Size: 200–300 sq.ft. Wall: HPL/SS Panels Floor: Antistatic vinyl HVAC: HEPA @ 0.3µ Lighting: 600 lux LED |
– Cost-effective – Laminar airflow – Integrated IVF lab support – Low maintenance |
| Advanced IVF OT | DR ORIVF EL | Includes OT and adjacent IVF laboratory. | Size: 300–500 sq.ft. Wall: SS304 with HPL cladding HVAC: ISO Class 7 Temp: 21–23°C Humidity: 45–55% |
– Seamless lab-OT operation – Pass box integration – Modular cleanroom walls – Pressure differential system |
| IVF Clean Room OT | DR ORIVF 1000CC | High-grade cleanroom OT for embryo transfer & ICSI. | ISO Class 6–7 HEPA: 99.997%@0.3µ Air changes: >25/hr Floor: Conductive ESD tiles |
– ISO-compliant air filtration – Epoxy-coated surfaces – Contamination control – Data logging systems |
| Mobile IVF OT | DR ORIVF PTU | Portable modular OT for remote or tier-2 city clinics. | Fully contained unit Power: Generator + UPS Built-in HVAC Size: ~300 sq.ft. |
– Transportable – All-in-one setup – Minimal installation – Quick deployment |
| Smart IVF OT | DR ORIVF IOT | Digitally integrated IVF OT with monitoring systems. | Real-time temp/humidity monitoring Integrated BMS Access control Surveillance |
– Remote monitoring – Live streaming of procedures – Touchless controls – IVF-specific software systems |
| Hybrid IVF OT | DR ORIVF OTPIR | Combines IVF OT with ultrasound & cryo-storage. | Imaging: Integrated USG Cooling: Cryogenic storage LED OT lights: 160,000 lux Modular partitions |
– Imaging + storage in OT – Advanced ventilation – One-way workflow – Seamless operation |
| HEPA Ceiling Modular OT | DR ORIVF LFC | Focuses on air cleanliness at the embryo work zone. | HEPA ceiling panels Vertical laminar flow FFU modules Air pressure >15 Pa |
– Max contamination control – Quiet FFU operation – Low particulate count – Ideal for embryo handling |
| Bio-safe IVF OT | DR ORIVF AMC | Prioritizes infection control & sterility. | Antimicrobial paint Flush doors UV-resistant fixtures SS304 touchpoints |
– Easy sterilization – Inbuilt biohazard control – Seamless corners – Anti-bacterial surfaces |
©2025-26. All Rights Reserved. Shresha Biortek