A simple device used for counting blood cells.
Kit consists of:
● Neubauer counting chamber.
● Cover Slips.
● RBC Pipette.
● WBC Pipette.
Item Name | CO2 Incubator | |||||
Model No. | DR-CO2-80UV | DR-CO2-80 | DR-CO2-80+ | DR-CO2-180UV | DR-CO2-180 | DR-CO2-180+ |
Sterilization | UV | 140°C | 180°C | UV | 140°C | 180°C |
Volume | 80L | 80L | 80L | 180L | 180L | 180L |
Microprocessor-based controller | Proprietary algorithm to control CO2 and temperature | |||||
Display | LCD touch display | |||||
Temp control range | Ambient +5°C- 60°C | |||||
Temp stability | ±0.1°C | |||||
Temp field uniformity | ±0.3°C (at 37°C ) | |||||
Timer function | 0 – 999hr 59 min. | |||||
CO2 measurement principle | Infrared (IR) detection | |||||
CO2 control range | 0-20% | |||||
CO2 display resolution | 0.10% | |||||
CO2 supply | 0.05~0.1MPa is recommended | |||||
Relative Humidity | Ambient humidity ~95% at 37°C | |||||
HEPA filtration | HEPA filters at the gas inlet, ISO 5 level, 5 minutes | |||||
Temperature recovery time | ≤10 min (open door 30sec room temperature 25°C set value 37°C) | |||||
O2 concentration recovery time | ≤5 min (open the door 30sec set value 5%) | |||||
MOC | The inner chamber is made up of stainless steel and outer chamber with MS with powder coating | |||||
Light | Florescent light | |||||
Historical data storage | 250,000 messages | |||||
Data export interface | USB interface | |||||
Scalability | Up to 2 units can be stacked. | |||||
Working environment temperature | 18~30°C | |||||
Power supply | 230V±10%, 50~60Hz | |||||
Inner Dimensions (L x D x H) mm | 450x450x450 | 550x600x600 | ||||
Outer Dimensions (L x D x H) mm | 650x650x750 | 750x800x850 |
Chamber design | Round and Rectangular |
---|---|
Vacuum range | Up to -760 mmHg |
Temperature range | Ambient+5°C to 150°C (Optional 200ºC) |
Temperature sensor | PT100 |
Temperature controller | Digital PID controller Display of SV & PV |
Inner chamber | Hermetically welded stainless steel 304 sheet |
External cabinet | Powder coated GI sheet |
Door | Solid door with clamp & toughened glass window |
Gasket | High temperature silicon gasket |
Shelves | Removable SS shelves |
Vacuum fittings | Vacuum valve / exhaust valves (Rubber hose) |
Standard fittings | Mains on/off switch Vacuum pump on/off switch Electric socket for vacuum pump |
Power supply | 220 Volts 50Hz |
Optional | KF25 flange vacuum connection 21 CFR compliance software Temperature up to 250°C All SS 304 construction (GMP) Digital vacuum control through solenoid valves PLC + HMI controller with USB interface Diaphragm valves for inert gas Timer 99 hours 59 min Oil-free vacuum pump |