Features
Economical and functional design suitable for blood donation setups
Strong frame made from epoxy powder-coated mild steel for durability
Padded seat and backrest with high-density foam for patient comfort
Upholstered in medical-grade, easy-to-clean vinyl fabric
Fixed or semi-reclining backrest to support relaxed posture during donation
Adjustable and cushioned armrests on both sides for donor support
Rubber-tipped legs to ensure stability and prevent floor damage
Lightweight and easy to reposition or store
Designed for comfort and safety during short- to mid-duration procedures
Specifications
Frame Material: Epoxy powder-coated mild steel
Upholstery: Medical-grade vinyl, water-resistant and easy to disinfect
Seat & Backrest: Cushioned with high-density foam
Armrests: Dual, cushioned, and adjustable
Backrest: Fixed or semi-reclining (varies by model)
Legs: 4-legged base with rubber stoppers
Finish: Smooth epoxy powder coating
Dimensions: Approx. 1700mm (L) x 600mm (W) x 900mm (H)
Weight Capacity: Up to 120 kg
Usage: Blood donation camps, clinics, mobile units, hospitals
Optional Features: Foldable design, reclining backrest, IV pole attachment
Measurement Method: Manual
Measurement Range: 0 – 300 mmHg
Accuracy: ±2 mmHg
Graduation: 2 mmHg increments
Cuff Size: 22 – 42 cm
Bladder Material: Latex or PVC, 2-tube system
Bulb Type: Rubber inflation bulb with chrome-plated release valve
Valve Type: Precision screw-type air control
Mercury Column: Glass tube with metal scale backing
Stand Type: Height-adjustable pole with 5-leg wheeled base
Tubing: Extendable tubing
Unit Height: Adjustable from 900 mm to 1300 mm
Weight: 4.5 – 6 kg
Operating Temperature: 10°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Method: Manual (Aneroid, Auscultatory)
Measurement Range: 0 – 300 mmHg
Accuracy: ±3 mmHg
Cuff Size Range: 22 – 42 cm
Dial Diameter: 50 mm
Manometer Type: Aneroid with 2 mmHg graduation
Bladder Material: Latex or PVC, 2-tube design
Bulb: Rubber inflation bulb with chrome-plated valve
Valve Type: Screw-type precision air release
Stethoscope: Optional, single-head compatible
Weight: 500 g
Operating Temperature: 5°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Parameters:
– SpO₂ (Oxygen Saturation): 0% – 100%
– Pulse Rate: 30 – 250 bpm
SpO₂ Accuracy: ±2% (for 70% – 100% range)
Pulse Rate Accuracy: ±2 bpm or ±2%
Display Type: Large LED or TFT screen
Waveform Display: Plethysmograph (real-time pulse waveform)
Alarm Functions: Adjustable thresholds for SpOâ‚‚ and PR, with sound and visual indicators
Power Supply:
– AC mains (100 – 240V, 50/60 Hz)
– Built-in rechargeable battery
Battery Backup: 4 – 8 hours of operation
Data Storage: Up to 72 hours or more
Connectivity: USB / RS232 / LAN
Weight: ~1.5 – 3 kg
Operating Environment:
– Temperature: 5°C – 40°C
– Humidity: ≤85% non-condensing
©2025-26. All Rights Reserved. Shresha Biortek