Air, Gas, Sound & Light
Measuring Range 1 ~ 200000 Lux
Resolution 1 Lux / 0.1 FC
Accuracy ±4.0% Full Scale
Units Lux & Fc unit selectable
Functions Max/Min Read
Power Source 1 x 9v (9F22)
Item Name | CO2 Incubator | |||||
Model No. | DR-CO2-80UV | DR-CO2-80 | DR-CO2-80+ | DR-CO2-180UV | DR-CO2-180 | DR-CO2-180+ |
Sterilization | UV | 140°C | 180°C | UV | 140°C | 180°C |
Volume | 80L | 80L | 80L | 180L | 180L | 180L |
Microprocessor-based controller | Proprietary algorithm to control CO2 and temperature | |||||
Display | LCD touch display | |||||
Temp control range | Ambient +5°C- 60°C | |||||
Temp stability | ±0.1°C | |||||
Temp field uniformity | ±0.3°C (at 37°C ) | |||||
Timer function | 0 – 999hr 59 min. | |||||
CO2 measurement principle | Infrared (IR) detection | |||||
CO2 control range | 0-20% | |||||
CO2 display resolution | 0.10% | |||||
CO2 supply | 0.05~0.1MPa is recommended | |||||
Relative Humidity | Ambient humidity ~95% at 37°C | |||||
HEPA filtration | HEPA filters at the gas inlet, ISO 5 level, 5 minutes | |||||
Temperature recovery time | ≤10 min (open door 30sec room temperature 25°C set value 37°C) | |||||
O2 concentration recovery time | ≤5 min (open the door 30sec set value 5%) | |||||
MOC | The inner chamber is made up of stainless steel and outer chamber with MS with powder coating | |||||
Light | Florescent light | |||||
Historical data storage | 250,000 messages | |||||
Data export interface | USB interface | |||||
Scalability | Up to 2 units can be stacked. | |||||
Working environment temperature | 18~30°C | |||||
Power supply | 230V±10%, 50~60Hz | |||||
Inner Dimensions (L x D x H) mm | 450x450x450 | 550x600x600 | ||||
Outer Dimensions (L x D x H) mm | 650x650x750 | 750x800x850 |
Shaker Speed | (20 – 250 RPM) (350,400 & 500 OPTIONAL) |
---|---|
Orbit Dia | ø 25 mm |
Accuracy | ± 2% of maximum speed |
Temperature range | 5˚C above RT to 60˚C & with cooling 5°C-60°C (Customize temperature options available) |
Resolution | 0.1°C |
Temp. accuracy | ± 0.3 ̊C |
Power supply | 230V ± 10%, 50Hz |
Category | DR-B2 |
---|---|
External Size (W*D*H) | 1383*775*2250 mm |
Internal Size (W*D*H) | 1210*600*660 mm |
Tested Opening | Safety height 10″ |
Max Opening | 470 mm |
Airflow Volume (Exhaust) | 100%: 1320 m³/h (776 cfm) |
Front Window | Motorized;Two-layer laminated toughened glass ≤6mm, Anti-UV |
Filter | ULPA,99.9995% efficiency at 0.12μm (02), filter life indicator |
Filter Guard Type | Aluminum alloy frame |
Noise | NSF 49 ≤60 dB |
Illumination | ≥1000 Lux |
Socket | 2, Total consumption ≤500W |
Display | Touch screen |
Tap | Water tap*1, Gas tap*1 |
Power Supply | AC220V,50/ 60Hz |
Consumption | 400W |
Alarm | Abnormal airflow velocity; Filter replacement; Front window at unsafe height |
Blower | One ECM motor, 230V AC; Speed adjustable, high efficiency and low power consumption |
Material | Working area: 304 stainless steel Frame,Decorative Plate: cold-rolled steel with anti- bacteria powder coating |
UV Lamp | 30W |
Germicidal UV Lamp | Emission of 253.7 nanometers for most efficient decontamination |
Certification | NSF 49 |
Illuminating Lamp | LED lamp, 20W*2 |
Standard Accessory | LED lamp*2, UV lamp*2, Base stand, SS water tap*1, Gas tap*1, Drain valve, Waterproof socket*2 |
Optional Accessory | Armrest, Airflow tester, Formalin fumigation sterilizer, Infrared sterilizer, exhaust duct |
Package Size (W*D*H) | 1540*1080*1900 mm |
Gross Weight | 340 kg |
©2025-26. All Rights Reserved. Shresha Biortek