Specifications:
Sample types: Venous blood, plasma, serum, urine, cerebrospinal fluid
Operating temperature: 10°C to 30°C
Operating humidity: Up to 90%
Repeatability: Coefficient of Variation (CV) <4%
Voltage requirement: AC 220V ±5%
Connectivity: RS-232 port for computer interfacing
Printer: Inbuilt thermal printer for report output
Specifications:
Operating temperature range: 2°C to 8°C
Internal volume: 400 liters (approx.)
Temperature alarm range: configurable for 2°C–8°C
High/low temperature alarm activation beyond 2°C–8°C limits
Dual temperature sensors (simulated load and ambient)
Visual and audio alarms for over/under temperature, door open, sensor error
Compressor control based on actual blood temperature
LCD screen displays real-time temperature, alarms, and 24-hour history
Chart recorder support with battery backup
Castor wheels: lockable and heavy-duty
Door: see-through double-glass with lock and insulated construction
Insulation: 70 mm cabinet, 80 mm door (CFC-free PUF)
Error self-diagnosis and display system
Voltage: standard 220V ±20V, 50Hz supply
Construction: inner AISI-304 SS, outer powder-coated CRCA
Safety features: thermostat, compressor overrun indicator, error alarms
| Model | DR-SP-350 | Absorbance accuracy |
±1% (7.332Abs at 260nm) |
|
| 4 Light Source | 0.02mm 0.05mm 0.2mm 1.0mm | Spectral resolution | <1nm | |
| Photometric accuracy | ±0.005A or ±1% | |||
| Detectors | HAMAMATSU UV Enhanced CMOS Line Array Sensing | Wavelength accuracy | ±1nm within | |
| Nucleic acid/ protein assay range | 0-27,500 ng/µl dsDNA
0.06-820 mg/mL BSA |
Wavelength Reproducibility | <±0.2nm | |
| Sample wavelength scanning | 190-850nm | |||
| Fluorescence sensitivity | DsDNA: 0.5pg/ul | Base measurement only | 0.5~2ul | |
| Fluorescence linearity | ≤1.5% | Sample base material | Quartz fiber and stainless steel | |
| Wavelength range | (190nm-850nm) | Testing time | <5S | |
| Sample volume requirements | 0.5-2ul | Power consumption at standby | 5W | |
| OD600 absorbance range | 0-6.000Abs | Data output method | USB | |
| OD600Absorbance stability | [0,3)≤0.5%,[3,4)<2% | Light source | Xenon flashing light | |
| OD600Absorbance accuracy | [0,2)≤0.005A,[2,3)≤1%,[3,4)≤2% | Power adapter | 24V DC | |
| Od600 Repeatability of absorbance |
[0,3)≤0.5%, [3,4)<2% |
Power consumption |
25W |
|
| Absorbance range | 0.02-300A (Equivalent to 10mm) | Dimension | W200mm×D260mm×H165mm | |
| Absorbance | 0.002Abs (0.2mm optical range) | Weight | 5Kg | |
Dr Labs pH-030 New Arrival with Precision Glass Bulb Electrode Portable PH Meter Liquid PH Alkalinity Value Digital Water Purity Tester Hydro tester Pen with Care Box & Calibration Screw Driver Suitable for Household RO Water Purifiers Filters, Drinking Water, Swimming Pools, Spas, Food, Drink, Gardening, Aquariums, Hydroponics A pH meter, also called a sensor or tester, is a device used to measure the alkalinity of a substance with a single-line LCD screen, a replaceable electrode, and a low power demand. A pH meter used to measure the pH of substance such as water, food, beer, or wine in laboratory, industrial, and food applications.
3-In-1 Digital TDS meter provides accurate readings for TDS (Total Dissolved Solids) EC (Electrical Conductivity) and temperature. Professional, Accurate, and Precise 3-in-1 TDS, EC, and Water Temperature Meter. The TDS meter has automatic temperature compensation in measurement mode. 9 minutes no operation, the meter will automatically shut down. Save power, extend battery life.
SALIENT FEATURES:
• Large back light LCD display shows mode indicator,
ph value, temperature
•Up to 3 point push -button calibration with
automatic buffer recognition
•Selectable pH buffer standards and temperature units.
•Automatically calculates and display electrode slope
after calibration
•Automatic temperature compensation (ATC) ensure
highly accurate measurements over the entire range.
•Automatic endpoint function freezes the stable
measured value
•Setup menu allows setting the pH buffer group,
number of calibration points, temperature unit,
auto-power off, etc.
•Reset function can resumes all setting to factory
default value
Dr Labs DR-PH-100 is an easy-to-use benchtop pH meter designed for daily testing and quality control.
This meter has a clear and bright back light LCD display that show the measured pH value, temperature,
mode indicators.
| Model | DR-PG-300 | DR-PG-500 |
|---|---|---|
| Make | DR Labs | DR Labs |
| Capacity | 300 g | 500 g |
| Readability (d) | 0.001g (1mg) | 0.001g (1mg) |
| Repeatability | 0.001 g | 0.001 g |
| Linearity | 0.002 g | 0.002 g |
| Pan Size | Ø 90 mm | Ø 90 mm |
| Response Time | 3 – 4 sec | 3 – 4 sec |
| Calibration | External | External |
| Display | Backlight LCD | Backlight LCD |
| Tara Range | Full | Full |
| Operating emperature | 10 to 40°C | 10 to 40°C |
| Power supply | AC 220V / 50Hz | AC 220V / 50Hz |
| Dimension | 325 x 300 x 225 | 325 x 300 x 225 |
| Weight | 4kg | 4kg |
Digital Portable Baby Weighing Scale/Weight Machine with Baby Tray (NEW MODEL) FEATURES: *Multi-Function Baby Weighing Scale with Min. Capacity of 10g & Max. Capacity of 100kg. *Equipped with a high precision “Stain-Gauge” Sensor and High Capability CPU to ensure Weight Accuracy. *Designed For Comfort The Smart Weigh Digital Baby Scale Is Beautifully Designed To Ensure The Comfort Of Your Baby. *TARE Feature i.e. Weigh the baby on a blanket or towel and press tare button to get the Baby Weight without any added weight. *Dual Usage Support i.e. Remove the Baby Tray and it can be used as a normal weighing scale. *Keep Track of Your Baby’s Weight To Make Sure Your Baby Is Getting The Proper Nutrition And Is Being Fed The Correct Amount.
| Brand |
|
| Model Number |
|
| Type |
|
| Measurement Depth |
|
| Meter Type |
|
| Accuracy |
|
| Functions |
|
| Suitable For |
|
| Model Name |
|
| Measurement Range |
|
| Model | DR-HMS-5LC |
|---|---|
| Make | DR Labs |
| Display | LCD |
| Max. Volume (ml) | 5000 |
| Speed (RPM) | 200-2000 RPM |
| Minimum Resolution (RPM) | 100 RPM |
| Top Plate Size | 190 x 190 mm |
| Plate Material | Ceramic |
| Max. Temp. (Plate surface) | 300°C |
| Temp. Sensor | PT100 |
| Temp. Controller | PID |
| Temp. Resolution | 0.1°C |
| Temp. Accuracy | ±0.5°C ( <100°C) ± 1° C (<300°C) |
| Timer | Yes |
| Power Wattage | Heating: 600 W, Stirring: 20 W |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 300 x 190 x 126 & 5 kgs |
| Model | DR-MS-300 |
|---|---|
| Make | DR Labs |
| Display | LCD |
| Max. Volume (ml) | 2000 |
| Speed (RPM) | 1250 RPM |
| Speed Display Style | Graph (Not numeric value) |
| Top Plate Size | 135 x 135 mm |
| Plate Material | Steel |
| Max. Temp. (Plate surface) | ±1°C ( <100°C) ± 3° C (<300°C) |
| Temp. Accuracy | 0~50°C, Automatic |
| Timer | 999 Minutes |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 230 x 180 x 120 & 2.6 kgs |
| Model | DR-GMP-30 |
|---|---|
| Make | DR Labs |
| pH Range | -2.000~20.000 pH |
| Resolution | 0.001, 0.01, 0.1 pH, Selectable |
| Accuracy & Calibration Points | ±0.002 pH & up to 5 points |
| pH buffer Option | USA,(pH 1.68, 4.01, 7.00 , 10.01, 12.45) |
| NIST (pH 1.68/4.01/6.86/9.18/12.45) | |
| DIN (pH 1.09, 4.65, 6.79, 9.23, 12.75) or user defined | |
| ORP (mV) Range | 0 ̴ ±1999.9 mV |
| ORP Calibration | 1 point calibration |
| ORP Resolution & Accuracy | 0.1, 1mV Selectable & ±0.2 mV |
| ORP Measuring Mode | Absolute mV or Relative mV |
| Conductivity Range | 0 ̴ 200mS / cm |
| Resolution & Accuracy | 0.01 / 0.1 / 1 & ±0.5% F Full Scale |
| Conductivity Cell Constant | 0.01/1/10 user defined |
| Temperature Coefficient | 0.0 ̴ 10.0 % per °C |
| Conductivity Calibration Points | Up to 5 points |
| Conductivity Calibration Solution | 10uS/cm, 48uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm |
| Compensation Modes | Linear or pure water |
| TDS Range | 0 ̴ 10ppt (Max. 200ppt, Depending on factor setting |
| Resolution & Accuracy | 0.01/0.1/1 & ± 1% Full Scale |
| TDS Factor | 0.0 ̴ 1.0 |
| Salinity Range | 0 ~ 80 ppt |
| Salinity Resolution & Accuracy | 0.01/0.1/1 & ± 1% Full Scale |
| Salinity Measurement Mode | Practical Salinity (PSU) or Seawater Measurement Standard (ppt) |
| Resistivity Range | 0 ̴ 100MΩ |
| Resistivity Resolution & Accuracy | 1/0.1/0.01 & ± 1% Full size |
| Temp. Range | 0 ̴ 100 °C, /32 ̴ 212°F |
| Temp. Compensation | Automatic or Manual |
| Temp. Accuracy | ± 0.5 °C, ±0.9 °F |
| Dimensions & Weight | 210 x 188 x 60mm & 1.2kg |
| Model | DR-PH-100 |
|---|---|
| Make | DR Labs |
| pH Range | -2 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ± 0.01 pH |
| Calibration Points | up to 3 points |
| pH Buffer options | USA (pH 4.01, 7.00, 10.01) or NIST |
| ORP Range (mV) | ± 1999 mV |
| ORP Accuracy(mV) | ± 1% FS ±1 digit |
| ORP Resolution(mV) | 1 mV |
| Temp. Range | 0 to 105°C |
| Temp. Accuracy | ± 0.5°C |
| Temp. Resolution | 0.1°C |
| Temp. Compensation | 0 to 100°C, Manual/Automatic |
| Hold Function | Available |
| Auto Off function | Available |
| Electrode Connector | BNC |
| Display | Backlight LCD |
| Dimensions & Weight | 210 x 205 x 75 mm & 1.5 kg |
| Model | DR-MB-7000 |
|---|---|
| Make | DR Labs |
| Capacity | 120g |
| Moisture Range | 0~100% |
| Moisture Resolution | 0.02% ~ 0.2%(sample≥2g) |
| Moisture Accuracy | ±0.2% |
| Readability | 0.001 g (1 mg) |
| Repeatability | ±0.001 g |
| Linearity | ±0.002 g |
| Minimum Capacity | 0.01g |
| Display | Touchscreen |
| Pan Size | Ø 90 mm |
| Sensor | German Loadcell |
| Calibration | External |
| Operating Temperature | 5 to 35°C |
| Heating Source | Halogen Lamp |
| Analysis Method | Manual, Timed, Automatic |
| Temp. Sensor | PT100 |
| Temp. Setting Range | 60 to 200°C |
| Temp. Setting Resolution | 1°C |
| Time Setting | 2 to 100 mins |
| Sample Library | Yes, 100 sample methods can be stored |
| Drying Modes | Standard, Fast & Soft |
| Data Output | RS-232 & USB-A |
| No. of Storage | 100 memory |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 350 x 215 x 192 mm & 4.5 kg |
| Model | DR-MA-220 | DR-MA-320 |
|---|---|---|
| Capacity | 220g | 320g |
| Make | DR Labs | DR Labs |
| Readablity | 0.0001g (0.1mg) | 0.0001g (0.1mg) |
| Linearity | ± 0.0003g | ± 0.0003g |
| Minimum Capacity | 0.01g | 0.01g |
| Display | LCD | LCD |
| Pan Size | Ø 90 mm | Ø 90 mm |
| Response Time | 4-6 sec | 4-6 sec |
| Calibration | Internal Calibration | Internal Calibration |
| Tare Range | Full | Full |
| Operating Temperature | 15 to 30°C | 15 to 30°C |
| Operating Humidity | 50-70% R.H | 50-70% R.H |
| Warm Up time | 30 min | 30 min |
| Units | g, ct, ozt, oz, GN, dwt, lb, mg | g, ct, ozt, oz, GN, dwt, lb, mg |
| Key Sound | Yes | Yes |
| Weighing Chamber Height | 210 mm | |
| Baud Rate | 1200, 2400, 4800, 9600 | 1200, 2400, 4800, 9600 |
| Class | I | I |
| Interface | RS-232C | RS-232C |
| Date Output | Command & Continuous | Command & Continuous |
| Power Supply | AC 220V / 50 Hz | AC 220V / 50 Hz |
| Dimensions & Weight | 220 x 360 x 345 mm & 9.5 kg | 220 x 360 x 345 mm & 9.5 kg |
| Model | DR-TB-200 |
|---|---|
| Make | DR Labs |
| Turbidity Range | 0~2000 NTU, 0~500 EBC, 0~9999 ASBC |
| Resolution | 0.01 (0~99NTU) 0.1 (100~999 NTU) 1(1000~2000NTU) |
| Accuracy | ±2% of reading (0~500NTU), ±3% of reading (501~2000NTU) |
| Calibration Points | 2 to 7 points |
| Calibration Standards | 0.02, 10, 200, 500, 1000, 1500, 2000 NTU |
| TSS Range | Depends on TSS conversion factor |
| TSS Accuracy | 3% of reading |
| Light Source | Infrared-emitting diode (850nm) |
| Detector | Silicone Photodiode |
| Stray Light | < 0.02 NTU |
| Sample Vial | 60(H) x 25(dia) mm |
| Memory & Data Output | 200 data sets & USB Data output |
| Operating Temperature | 0~50°C |
| Display | 4.5″ TFT LCD |
| Power Supply | DC12V Power Adapter |
| Dimensions & Weight | 250 x 177 x 96 mm & 1.2 kg |
| Model | DR-TDS-100 |
|---|---|
| Make | DR Labs |
| Conductivity Range | 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0 mS/cm (5 auto ranges) |
| Conductivity Resolution | 0.01, 0.1, 1 |
| Conductivity Accuracy | ± 1% F.S |
| Calibration Points | up to 3 points |
| Buffer options | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Temp. Compensation | 0 to 100°C, Manual/Automatic |
| Temp. Coefficient | 0.0~10.0%/°C |
| Cell Constant | K=0.1, 1, 10 |
| Normalization Temp. | 25°C |
| TDS Range | 0~10 ppt (max. 200 ppt, depending on factor setting & ec range |
| TDS Accuracy | ± 1% F.S |
| TDS Factor | 0.1 to 1.0 (Default 0.5) |
| Temp. Range | 0 to 105°C |
| Temp. Resolution | 0.1°C |
| Temp. Accuracy | ±0.5°C |
| Hold & Auto Off function | Both Available |
| Electrode Connector | 3 pin |
| Display | Backlight LCD |
| Power | DC9V, AC220V, 50 Hz |
| Dimensions & Weight | 210 x 205 x 75 mm & 1.5 kg |
| Model | DR-IF-30 | DR-IF-50 | DR-IF-100 | DR-IF-150 |
|---|---|---|---|---|
| Make | DR Labs | DR Labs | DR Labs | DR Labs |
| Capacity of Ice Flaker | 30 kg / 24 hr | 50 kg / 24 hr | 100 kg / 24 hr | 150 kg / 24 hr |
| Storage Capacity | 10 kgs | 15 kgs | 40 kgs | 40 kgs |
| Storage Bin | ABS Plastic | ABS Plastic | ABS Plastic | ABS Plastic |
| Cooling Method | Air (inside R290A refrigerant) | Air (inside R290A refrigerant) | Air (inside R290A refrigerant) | Air (inside R290A refrigerant) |
| Ambient Temperature | Below 25°C for optimum working | Below 25°C for optimum working | Below 25°C for optimum working | Below 25°C for optimum working |
| Construction | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Noise Level | ≤52 dB | ≤52 dB | ≤52 dB | ≤52 dB |
| Water Supply | 3/4″ BSP | 3/4″ BSP | 3/4″ BSP | 3/4″ BSP |
| Refrigerant | R290A | R290A | R290A | R290A |
| Power Supply | AC 220 V / 50 Hz | AC 220 V / 50 Hz | AC 220 V / 50 Hz | AC 220 V / 50 Hz |
| Input Power | 300 W | 380 W | 520 W | 680 W |
| Dimensions | 330 x 470 x 605 mm | 400 x 540 x 700 mm | 500 x 611 x 950 mm | 500 x 611 x 950 mm |
| Gross Weight | 26 kgs | 36 kgs | 58 kgs | 60 kgs |
| Model | DR-UV-300 |
|---|---|
| Make | DR Labs |
| Optical System | Single Beam, Grating 1200 lines/mm |
| Wavelength Range | 190~1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Setting | Automatic |
| Wavelength Accuracy | ± 0.3 nm |
| Wavelength Repeatability | ± 0.1 nm |
| Cell Holder | 10mm manual 4-cell holder |
| Photometric Range | -0.3 ~ 3A, 0~200%T, 0~9999C |
| Photometric Accuracy | 0.05% T |
| Photometric Repeatability | ±0.2% T |
| Stray Light | ≤0.05%T |
| Stability | ±0.002A/h @500nm |
| Baseline Flatness | ±0.002A/h @500nm |
| Display | 128 * 64 LCD |
| Photometric Mode | T, A, C |
| Detector | Imported Japanese Silicon Photodiode |
| Light Source | Imported Japanese D2 & Tungsten Halogen Lamp |
| Output | USB Port & Parallel Port |
| Power Supply | AC 220V / 50Hz |
| Dimensions & Weight | 700 × 580 × 340 mm & 20 kgs |
| Model | DR-V-721 |
|---|---|
| Make | DR Labs |
| Optical System | CT Single Beam, Grating 1200 lines/mm |
| Wavelength Range | 320~1020 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Interval | 1 nm |
| Wavelength Accuracy | ± 2 nm |
| Wavelength Repeatability | 1 nm |
| Photometric Accuracy | ± 1% T |
| Photometric Repeatability | 0.5% T |
| Photometric Range | 0 – 1.999A, 0-199.9%T |
| Stray Light | ≤0.3%T@340nm |
| Stability | ±0.004A/h @500nm |
| Display | 4 Digit LCD |
| Photometric Mode | T, A, C |
| Detector | Silicon Photodiode |
| Light Source | Tungsten Lamp |
| Power Supply | AC 220V / 50Hz |
| Dimensions & Weight | 450 × 520 × 320 mm & 10 kgs |
| Model | DR-P-650 |
|---|---|
| Make | DR Labs |
| Frequency | 18-28 kHz Auto Tracking |
| Frequency tracking accuracy | 1 Hz real-time tracking |
| Processing Capacity | 0.5ml to 500 ml |
| Standard Probe | Ø 6 mm (1/4″) |
| Display8″ Touchscreen | 8″ Touchscreen |
| Display Function | Temperature, Power, Time, Gap Time |
| Temperature Range | 0-99°C |
| Timer | Yes upto 99 hours, 59 mins, 59 secs |
| Alarm Function | Over temperature, over current, over load, transducer abnormality, etc. |
| Operating Table | Electrically operated motorized |
| Lighting | Available inside cabinet |
| Data Memory | 9 memory group |
| Output Power | 650W (adjustable) |
| Power Source | AC 220V / 50 Hz |
| Dimensions & Weight | 280 x 280 x 490 mm – 10.2 kg |
| Model | DR-V-60 |
|---|---|
| Make | DR Labs |
| Measuring Range (mpa.s) | 20 to 20,00,000 mpa.s |
| Measurement Resolution | 0.01 mpa.s (Full Scale) |
| Speeds | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 RPM |
| No. of Speed | 8 speed settings |
| No. of Standard Spindle | 4 |
| Display | LCD |
| Auto Scan Function | Can automatically scan and recommend the preferred combination of rotor and speed |
| Temp. Monitoring | Optional – Feature available |
| Measurement Accuracy | ±1% F.S |
| Repeatability | ± 0.5% F.S |
| Output | RS 232C Interface |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 300 × 300 × 450 mm & 9 kgs |
| Model | DR-WYA-2S |
|---|---|
| Make | DR Labs |
| Measurement range refractive index nD | 1.3000 to 1.7000 |
| Measurement range refractive index Brix | 0 to 100 % Brix |
| Accuracy refractive index nD | ≤ ±0.0002 |
| Accuracy (Dissolve solids Brix) | ± ≤ 0.1% |
| Temperature Resolution | 0.1°C |
| Temperature Range (Min 0.1°C) | 0~50°C |
| Correcting range of brix versus | 15~45°C |
| Usage Temperature Range | Ambient to 35°C |
| Interface | RS232C |
| Power | AC 220V / 50 Hz |
| Dimensions & Weight | 370 x 240 x 470 mm – 12 kg |
SPECIFICATIONS:
| Model | DR-20RE | DR-30RE | DR-50RE |
|---|---|---|---|
| Rotating Speed | Color LCD Screen; 0~310rpm/min | Color LCD Screen; 0~310rpm/min | Color LCD Screen; 0~200rpm/min |
| Evap. Capacity | Max.25ml/min (H2O) | Max.27ml/min (H2O) | Max.43ml/min (H2O) |
| Temp. range/precision | Microcomputer PID controller; Water Bath | RT.-99 ºC±0.5 ºC Oil Bath RT.-210ºC±2ºC | |
| Bath Material | Integral Teflon compound heating bath with safe handle, which prevents from scald; the medium sized bath volume makes distillation fast. | ||
| Bath Size | Dia 23×13cm | Dia 26×15cm | Dia 29×17cm |
| Positive&Negative Rotating | Intermittent positive and negative rotating function with timing function (0-60s) for drying process | ||
| Lif | Automatic balance lifting which can be controlled by either button-press or Color LCD screen; the lifting length is 150mm, with fixed safety distance of 60mm, which prevents crashing. | ||
| Temp. Set | Rotating switch coding for temperature setting with big LCD screen display. | ||
| Safety | Anti-dry prevention function which makes flask automatic lifting; instrument will stop at the set timing (0-999min); automatic lifting and standby alarm protection in abnormal or over temperature state. | ||
| Heater Powe | 1.5KW | 1.5KW | 1.5KW |
| Sealing | Imported PTFE and special complex compounded with special technique, which ensures good sealing and improves the anti-corrosion and durability property. | ||
| Condenser | Vertical 3-layered coil condenser with big condensation area, equipped with drip point and backflow prevention, which effectively increases the evaporation efficiency. | ||
| Condense Area | 0.18m 2 | 0.21m2 | 0.31m 2 |
| Environment Temp | 5ºC~40 ºC | ||
Technical Specifications
| Model DR-BDDU | |
| Parameters | Values |
| Specific Conductivity | 0.8-1 μs/cm |
| Biological Activity (distillate quality) | Pyrogen Free |
| Organic Matter | Nil |
| Total Solids | 0.1 mg/ltr |
| Silica | <0.01 mg/ltr |
| Output Capacity (Approx.) | 2.5 – 4 Ltr/hr |
| Power Rating (Total) | 6 KW |
| Cooling Water Consumption (Approx.) | 150 Ltr/Hr |
| Specification | Details |
|---|---|
| Model | DR-UC-10P |
| Make | DR Labs |
| Theoretical Capacity | 10 Litre |
| Actual Water Filling | 8 Litre |
| Tank Size (mm) | 300 x 240 x 150 |
| Overall Size (mm) | 330 x 270 x 310 |
| Ultrasonic Power | 420 W |
| Heating Power | 1000 W |
| Tank, Body, Lid Material | Stainless Steel 304 |
| Time Setting | 1 to 99 mins / Always On |
| Heating Temp. | Ambient to 80°C |
| Display & Ultrasonic Frequency | LED Display, 40 kHz |
| Power Supply | 220v / 50 Hz |
| Weight | 9 kg |