DR Labs Vacuum ovens are used to dry heat-sensitive materials like powder and extract moisture. Vacuum drying reduces the boiling point, reducing losses of components other than water. Samples are gently heated and dried, leaving virtually no residue. Vacuum ovens are used for a variety of purposes, including moisture content assessment, dry sterilization, solid purification, and outgassing. We provide a variety of optional accessories for vacuum ovens, including an explosion-proof heater, digital timer, PLC-based HMI controller, RS485 computer interface, 21 CFR software, data logger and circular chart recorder, HEPA filter air inlet, and so on.
Versatile Chamber Designs:
Leak-Proof Arc Welding:
High-Temperature Silicon Gasket:
Secure and Durable Door Clamps:
Temperature Control Range:
Advanced PID Controller with Dual Display:
Optional Advanced Features:
Chamber design | Round and Rectangular |
---|---|
Vacuum range | Up to -760 mmHg |
Temperature range | Ambient+5°C to 150°C (Optional 200ºC) |
Temperature sensor | PT100 |
Temperature controller | Digital PID controller Display of SV & PV |
Inner chamber | Hermetically welded stainless steel 304 sheet |
External cabinet | Powder coated GI sheet |
Door | Solid door with clamp & toughened glass window |
Gasket | High temperature silicon gasket |
Shelves | Removable SS shelves |
Vacuum fittings | Vacuum valve / exhaust valves (Rubber hose) |
Standard fittings | Mains on/off switch Vacuum pump on/off switch Electric socket for vacuum pump |
Power supply | 220 Volts 50Hz |
Optional | KF25 flange vacuum connection 21 CFR compliance software Temperature up to 250°C All SS 304 construction (GMP) Digital vacuum control through solenoid valves PLC + HMI controller with USB interface Diaphragm valves for inert gas Timer 99 hours 59 min Oil-free vacuum pump |
Model | DR-MC-15 |
---|---|
Make | DR Labs |
Speed Range | 500~15000 RPM |
Speed Increament | 100 RPM |
Max. RCF (x g) | 15100, increment: 100 |
Speed Accuracy | ±20 |
Rotor Capacity | 0.2ml/0.5ml/1.5ml/ 2ml×12 |
Timer | Timer: 30s~99 min |
Motor | Brushless DC Motor |
Safety Features Noise | Door interlock, Over-speed detection, Over-temperature detection, Automatic internal diagnosis |
Acceleration/Brake Time | Acceleration: 30s, Braking:10s |
Power Supply | AC 220V / 50Hz |
Dimension | 256 x 225 x 155 mm & 6 kg |
Weight | 6 kgs |
Category | DR-B2 |
---|---|
External Size (W*D*H) | 1383*775*2250 mm |
Internal Size (W*D*H) | 1210*600*660 mm |
Tested Opening | Safety height 10″ |
Max Opening | 470 mm |
Airflow Volume (Exhaust) | 100%: 1320 m³/h (776 cfm) |
Front Window | Motorized;Two-layer laminated toughened glass ≤6mm, Anti-UV |
Filter | ULPA,99.9995% efficiency at 0.12μm (02), filter life indicator |
Filter Guard Type | Aluminum alloy frame |
Noise | NSF 49 ≤60 dB |
Illumination | ≥1000 Lux |
Socket | 2, Total consumption ≤500W |
Display | Touch screen |
Tap | Water tap*1, Gas tap*1 |
Power Supply | AC220V,50/ 60Hz |
Consumption | 400W |
Alarm | Abnormal airflow velocity; Filter replacement; Front window at unsafe height |
Blower | One ECM motor, 230V AC; Speed adjustable, high efficiency and low power consumption |
Material | Working area: 304 stainless steel Frame,Decorative Plate: cold-rolled steel with anti- bacteria powder coating |
UV Lamp | 30W |
Germicidal UV Lamp | Emission of 253.7 nanometers for most efficient decontamination |
Certification | NSF 49 |
Illuminating Lamp | LED lamp, 20W*2 |
Standard Accessory | LED lamp*2, UV lamp*2, Base stand, SS water tap*1, Gas tap*1, Drain valve, Waterproof socket*2 |
Optional Accessory | Armrest, Airflow tester, Formalin fumigation sterilizer, Infrared sterilizer, exhaust duct |
Package Size (W*D*H) | 1540*1080*1900 mm |
Gross Weight | 340 kg |
©2025-26. All Rights Reserved. Shresha Biortek