Vertical gel electrophoresis is a widely used technique in molecular biology and biochemistry for separating proteins and nucleic acids based on their size and charge. The DR Labs vertical electrophoresis units are designed as single-molded systems, eliminating the need for fabrication or adhesive joints, ensuring a leak-proof experience. These units feature a uniquely designed caster assembly that is simple to operate and guarantees a secure, leak-free performance.
SPECIFICATIONS | PARAMETERS | |
---|---|---|
Model No. | DR-VE1 | Â DR-VE2 |
Dimension(LxWxH)(mm) | 185*108*125 | 153*183*159 |
Gel size (mm) | 83*73 | 83*73 |
Comb Specifications | 1.0mm :11 teeth 1.5mm: 11 teeth |
1.0mm: 11 teeth/ 15teeth 1.5mm: 11 teeth/ 15teeth 0.75mm: 11 teeth/15teeth |
Maximum Buffer Capacity | 0.5L | 1.6 L |
Number of Gels | 1-2 | 1-4 |
SPECIFICATIONS | PARAMETERS | |
---|---|---|
Model No. | Â DR-VE1 | Â DR-VE2 |
Number of Gels | 1-2 | 1-4 |
Dimension (LxWxH)(mm) | 185*108*125 | 153*183*159 |
Transfer size (mm) | 70*90 | 70*90mm |
Buffer volume | 0.5L | 1.6L |
The Power Pack DR Labs is an advanced rectifier device designed to convert alternating current (AC) to direct current (DC) for high-precision applications. Its versatile design supports constant voltage and current control, making it an ideal solution for a wide range of laboratory experiments such as nucleic acid gel electrophoresis, protein gel electrophoresis, Western blotting, and protein transfer. This device is widely used in biological and medical fields for precise, stable, and reliable performance.
Input Power Supply: | 180V-240V |
---|---|
AC Frequency: | 50Hz/60Hz |
Ambient Temperature: | 4°C to 40°C |
Environmental Humidity: | 10%-70% |
OUTPUT RANGE: | |
Voltage: | 6V-600V (accuracy 1V) |
CONTROL ACCURACY: | |
Voltage Setting: | <100V voltage stability accuracy: <1V >100V voltage stability accuracy: <±1% |
CURRENT SETTING: | |
CURRENT SETTING: | <100mA current stability accuracy: <1mA >100mA current stability accuracy: <±1% |
Rated Output Power: | 300W |
Dimensions: | 265mm (L) x 215mm (W) x 120mm (H) |
Output Quantity: | Positive, negative A/B four groups. |
WORKING MODES: | |
Constant Voltage (U Mode): | Default mode, ensures constant voltage during operation. |
Constant Current (I Mode): | Provides stable current control for sensitive applications. |
Gradient Voltage/Current (Gradient U/I Mode): | Allows setting of three different voltage or current segments for more complex protocols. |
SPECIFICATIONS:
Temperature range | -10° C to -40°C |
---|---|
Temperature accuracy | ±0.5°C |
Temperature Uniformity | ±0.1°C |
Temperature controller | Dual display PID controller |
Temperature sensor | PT100 |
Inner chamber | SS 304 |
External cabinet | Powder coated GI sheet |
Insulation | Glass wool |
Door | Insulated door Mechanical latch / clamp |
Heaters | Resistance wire heaters |
Shelves | SS wire mesh (removable) |
Standard fittings | Mains on/off switch Load Indicator Fan on/off switch |
Power supply | 220 Volts 50Hz |
Optional | GMP construction (Inner & outer SS304) PLC + HMI controller w/ USB interface 21 CFR Part 11software Data logger w/ USB interface Thermal printer Inner chamber LED light |
Temperature range | 5°C to 60°C |
Temperature controller | Digital PID controller |
Temperature accuracy | ±1% |
Temperature sensor | PT-100 |
Humidity range | 50% to 90% RH |
Humidity controller | Digital PID controller |
Humidity accuracy | ±3% |
Light | 150-170 micromole/m2/sec |
Light timer | 24×7 weekly digital timer |
Construction | Double walled |
Exterior | Mild steel powder coated |
Interior | Stainless steel 304 |
Outer door | Single or double solid doors with lock & key |
Inner door | Glass door to view samples |
Shelves | 3 to 12 (Height adjustable) |
Safety | Audio / visual alarm for temperature deviation |
Optional | Exterior made of stainless steel 304 / 316 PLC with HMI interface Data logger with USB interface Password protection for controller Caster wheels |
Power supply | 220 Volts / 50 Hz |
 SIZE:
Model | Dimensions (mm) | Volume (Litres) | Volume (Cu. Ft.) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DR-SGC171 | 505 x 415 x 830 | 171 | 6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DR-SGC209 | 600 x 550 x 910 | 300 | 10 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
STANDARD SIZE:
DR-SGC340 |
650 x 580 x 900 | 340 | 12 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DR-SGC400 | 700 x 640 x 900 | 400 | 14 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DR-SGC580 | 775 x 775 x 970 | 580 | 20 |
Chamber design | Round and Rectangular |
---|---|
Vacuum range | Up to -760 mmHg |
Temperature range | Ambient+5°C to 150°C (Optional 200ºC) |
Temperature sensor | PT100 |
Temperature controller | Digital PID controller Display of SV & PV |
Inner chamber | Hermetically welded stainless steel 304 sheet |
External cabinet | Powder coated GI sheet |
Door | Solid door with clamp & toughened glass window |
Gasket | High temperature silicon gasket |
Shelves | Removable SS shelves |
Vacuum fittings | Vacuum valve / exhaust valves (Rubber hose) |
Standard fittings | Mains on/off switch Vacuum pump on/off switch Electric socket for vacuum pump |
Power supply | 220 Volts 50Hz |
Optional | KF25 flange vacuum connection 21 CFR compliance software Temperature up to 250°C All SS 304 construction (GMP) Digital vacuum control through solenoid valves PLC + HMI controller with USB interface Diaphragm valves for inert gas Timer 99 hours 59 min Oil-free vacuum pump |
Construction | Economy Model | Double Walled Model | Triple Walled Model |
---|---|---|---|
MOC Exterior | Painted MS sheet | SS 304 (mirror finish) | SS 304 (mirror finish) |
No. of walls | Two | Two | Three |
Lid | Polished MS | SS 304 | SS 304 |
Interior | SS 304 with silicon gasket | ||
Working Pressure | 15-30 psi | ||
Working Temp. | 121°C to 134°C | ||
Controller | Auto set to 15psi & 121°C | ||
Pressure display | Analogue dial gauge | ||
Timer | Mechanical timer | ||
Programmable | Programmable automatic start timer | ||
Hydraulic tested | Hydraulically Tested up to 40 psi (ASME Guideline) | ||
Lick lock | Single hand easy lock system for operating and closing | ||
Program for heating sterilization, exhaust, warming and completion. | |||
Basket | Stainless steel basket | Stainless steel basket | Not Required |
Power supply | 220 Volts 50Hz | ||
Standard Fittings | Low water indicator; Automatic pressure switch; Pedal lifting device Steam release valve; Water outlet valve; Spring loaded safety valve Power cable with three pin tops | ||
Optional Accessories |
|
©2025-26. All Rights Reserved. Shresha Biortek