ELECTRO MEDICAL EQUIPMENTS

Product Categories

1 Channel Electrocardiograph

Specifications:

  • 1-channel ECG acquisition

  • 12-lead ECG recording with lead switching

  • Built-in thermal printer for real-time ECG output

  • Prints on 50mm wide paper

  • Operates on AC power with internal battery backup

  • Simple display and keypad for essential control

  • Measurement of basic ECG parameters (heart rate, intervals)

  • Basic filtering system for noise reduction

  • Limited internal memory for recent ECG recordings

  • Compact form factor designed for handheld use

  • Patient safety protections including input isolation

  • Complies with standard medical equipment regulations

3 Channel Electrocardiograph

Specifications:

  • 3-channel simultaneous ECG acquisition

  • 12-lead ECG recording

  • Integrated thermal printer for ECG report generation

  • Prints on 80mm wide paper

  • Built-in rechargeable battery with AC power operation

  • LCD display with functional navigation keys

  • Standard measurements: heart rate, PR/QRS/QT intervals, axes

  • Noise filters: baseline, muscle, AC interference

  • USB or SD card support for data export (model dependent)

  • Complies with medical safety and electromagnetic standards

  • Patient isolation and overvoltage protection included

  • Memory for limited number of ECG records

12 channel Electrocardiograph

Specifications

  • 12-channel electrocardiograph system

  • 8-inch high-resolution color touchscreen display

  • Alphanumeric keyboard for data input

  • Internal memory capacity for storing up to 800 ECG records

  • USB flash drive support for storage expansion and data export

  • Built-in thermal printer supporting standard thermal and A4 fax paper

  • USB connectivity for external printer support

  • Data communication via LAN and optional internal Wi-Fi

  • Export formats supported: PDF, SCP, FDA-XML, DICOM

  • Supports standard communication protocols: DICOM Worklist, HL7, GDT

  • 24-bit analog-to-digital conversion for precise signal detection

  • Common-mode rejection ratio (CMRR) greater than 140dB

  • Real-time ECG waveform freezing and review up to 120 seconds

  • Automatic measurement and interpretation validated with CSE, AHA, and MIT databases

  • Built-in Glasgow interpretation algorithm

  • Optional vector ECG analysis feature

  • Compatible with optional SE-1515 data management software and Smart ECG Viewer

  • Rolling stand or trolley configuration available

  • Basic model variant offered for simplified applications

Sphygmomanometer LCD (Backlight)

Specifications:

  • Measurement Method: Oscillometric  manual inflation

  • Measurement Range:
    – Systolic: 60 – 260 mmHg
    – Diastolic: 40 – 199 mmHg
    – Pulse Rate: 40 – 180 bpm

  • Accuracy:
    – Pressure: ±3 mmHg
    – Pulse: ±5%

  • Display Type: Large LCD with backlight

  • Cuff Size: 22 – 42 cm

  • Power Supply:  batteries or AC adapter
  • Auto Power Off: After 1 minute of inactivity

  • Weight: 300 – 400 g
  • Operating Temperature: 5°C – 40°C

  • Humidity Range: 15% – 85% RH non-condensing

Sphygmomanometer Mercurial (Floor Model)

Specifications:

  • Measurement Method: Manual

  • Measurement Range: 0 – 300 mmHg

  • Accuracy: ±2 mmHg

  • Graduation: 2 mmHg increments

  • Cuff Size: 22 – 42 cm

  • Bladder Material: Latex or PVC, 2-tube system

  • Bulb Type: Rubber inflation bulb with chrome-plated release valve

  • Valve Type: Precision screw-type air control

  • Mercury Column: Glass tube with metal scale backing

  • Stand Type: Height-adjustable pole with 5-leg wheeled base

  • Tubing: Extendable tubing

  • Unit Height: Adjustable from 900 mm to 1300 mm

  • Weight: 4.5 – 6 kg

  • Operating Temperature: 10°C – 40°C

  • Storage Temperature: -10°C – 50°C

Sphygmomanometer Mercurial (Wall Model)

Specifications:

  • Measurement Method: Manual

  • Measurement Range: 0 – 300 mmHg

  • Accuracy: ±2 mmHg

  • Graduation: 2 mmHg increments

  • Cuff Size: 22 – 42 cm

  • Bladder Material: Latex or PVC, 2-tube system

  • Bulb Type: Rubber inflation bulb with chrome-plated valve

  • Valve Type: Precision screw-type air release

  • Mercury Column: Glass tube with metal backing scale

  • Mounting: Wall-mount bracket with hardware

  • Weight: 2.5 – 3.2 kg

  • Operating Temperature: 10°C – 40°C

  • Storage Temperature: -10°C – 50°C

Sphygmomanometer Mercurial (Desk Model)

Specifications:

  • Measurement Method: Manual

  • Measurement Range: 0 – 300 mmHg

  • Accuracy: ±2 mmHg

  • Graduation: 2 mmHg increments

  • Cuff Size: 22 – 42 cm

  • Bladder Material: Latex or PVC, 2-tube design

  • Bulb: Rubber inflation bulb with air-release valve

  • Valve Type: Chrome-plated screw-type

  • Mercury Column: Glass tube with metal scale backing

  • Base Material: Powder-coated metal or ABS plastic

  • Weight: 2.5 – 3 kg

  • Operating Temperature: 10°C – 40°C

  • Storage Temperature: -10°C – 50°C

Sphygmomanometer (Universal)

Specifications:

  • Measurement Method: Manual (Aneroid, Auscultatory)

  • Measurement Range: 0 – 300 mmHg

  • Accuracy: ±3 mmHg

  • Cuff Size Range: 22 – 42 cm

  • Dial Diameter: 50 mm

  • Manometer Type: Aneroid with 2 mmHg graduation

  • Bladder Material: Latex or PVC, 2-tube design

  • Bulb: Rubber inflation bulb with chrome-plated valve

  • Valve Type: Screw-type precision air release

  • Stethoscope: Optional, single-head compatible

  • Weight: 500 g

  • Operating Temperature: 5°C – 40°C

  • Storage Temperature: -10°C – 50°C

Sphygmomanometer (Digital)

Specifications:

  • Measurement Method: Oscillometric

  • Measurement Range:
    – Systolic: 60 – 260 mmHg
    – Diastolic: 40 – 199 mmHg
    – Pulse Rate: 40 – 180 bpm

  • Measurement Accuracy:
    – Pressure: ±3 mmHg
    – Pulse: ±5%

  • Display Type: LCD/LED digital screen

  • Memory Capacity: 60 – 120 readings per user

  • Power Supply:  batteries or AC adapter

  • Cuff Size: 22 – 42 cm

  • Auto Power Off: After 1 minute of inactivity

  • Weight: 300 – 400 g

  • Operating Temperature: 5°C – 40°C

  • Humidity Range: 15% – 85% RH non-condensing

Pulse Oximeter (Table-top)

Specifications:

  • Measurement Parameters:
    – SpO₂ (Oxygen Saturation): 0% – 100%
    – Pulse Rate: 30 – 250 bpm

  • SpO₂ Accuracy: ±2% (for 70% – 100% range)

  • Pulse Rate Accuracy: ±2 bpm or ±2%

  • Display Type: Large LED or TFT screen

  • Waveform Display: Plethysmograph (real-time pulse waveform)

  • Alarm Functions: Adjustable thresholds for SpO₂ and PR, with sound and visual indicators

  • Power Supply:
    – AC mains (100 – 240V, 50/60 Hz)
    – Built-in rechargeable battery

  • Battery Backup: 4 – 8 hours of operation

  • Data Storage: Up to 72 hours or more

  • Connectivity: USB / RS232 / LAN

  • Weight: ~1.5 – 3 kg

  • Operating Environment:
    – Temperature: 5°C – 40°C
    – Humidity: ≤85% non-condensing

Pulse Oximeter (Fingertip)

Specifications

  • Measurement Parameters: SpO₂ (Oxygen Saturation) & Pulse Rate

  • SpO₂ Measurement Range: 70% – 100%

  • Pulse Rate Range: 30 – 250 bpm

  • Accuracy (SpO₂): ±2%

  • Accuracy (Pulse Rate): ±2 bpm or ±2%

  • Display Type: OLED or LED

  • Power Supply: 2 × AAA batteries

  • Battery Life: ~20 – 30 hours of continuous use

  • Weight: Approx. 50 – 60 grams

  • Operating Temperature: 5°C – 40°C (41°F – 104°F)

  • Storage Temperature: -10°C – 50°C

Electrocardiograph (3 Channel)

Print-out Format :
  • A) Auto mode-3, 3+R with medians, 3+R with  Medians + Axis + measurements & interpretation
  • B) Manual mode -3 channel three different lead selected from keypad

Electrocardiograph (1 Channel)

Technical Specifications

  • A/D Resolution: 10 Bit
  • Lead Selection: Standard 12 Leads
  • Filters: Low pass filter: 35, 100Hz , High pass filter: 0.05Hz, Notch filter 50 Hz (on/off)
  • Acquisition : Auto/Manual
  • Memory : Last patient
  • Input impedance : >100 M ohm
  • Frequency Response        0.05-100Hz
  • CMRR : 100dB
  • Time Constant : 3.2 sec
  • Sensitivity : 5mm/mV, 10mm/mV,20mm/mV
  • Leakage Current : <10 micro Ampere

Electrocardiograph (12 Channel)

  • A/D Resolution : 24 Bit
  • Lead Selection : Standard 12 Leads
  • Notch Filter : 50/60 Hz
  • Noise Level : ≤12µVp-p
  • Acquisition : Auto/Manual
  • Memory : 1000 patients
  • Input impedance : ≥50M ohm(10Hz)
  • Frequency Response : 0.05-150Hz
  • CMRR : > 60 dB,> 100 dB
  • Time Constant : ≥3.2 sec
  • Sensitivity : 2.5, 5, 10, 20, 40mm/mV
  • Measurement : HR, P-R interval, P Duration, QRS Duration, T Duration,
    Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5) amplitude,
    S(V1) amplitude, R(V5)+S(V1) Amplitude

Anesthesia Workstation

  • Upgraded integrated Circle Absorber, With twins large volume CO₂ absorbing Efficiency
  • With non-return respiratory valve and expiratory valve on it avoid gas back flowing
  • With APL valve on it, the airway pressure could be adjusted freely With ‘Manual/Ventilation
  • Switch On it, easily and quickly change
  • One vaporizer /isoflurane /halothane / Sevoflurane
  • Rust Proof Epoxy Coated High Strength Frame Pipeline Attachment for O₂, N₂O
  • One yoke for O₂ (5 ltrs) cylinder and one for N₂O (5ltrs) cylinder
  • Select tec bar with provision to mount 2 Vaporizers

Portable Anesthesia Machine

  • Non-return / Pressure Relief Valve: Minimizes risk of back flow of gases, blows off when pressure exceeds 125 Cm H₂O.
  • Oxygen Flush: Emergency oxygen flush switch at table level to give 35 – 70 Ltrs/min for emergencies.
  • O₂ failure Warning Alarm: Self activated electro-pneumatic audio visual warning device to indicate drop in O₂ pressure below 2.5 Bar.
  • Anti-Hypoxic Guard: Mixing device to proportion the N₂O in such a way that minimum of 25% O₂ is always delivered from the rotameter.
  • Common Gas Outlet (CGO): Conveniently located CGO with ISO tapers for 22 mm & 15 mm connections
  • Pipe Line Gas Inlets: Non-Interchangeable Screw Threaded (NIST) pipeline inlets
  • Pressure Gauges: Large diameter

Anesthesia Machine

  • Two Capacious drawers for keeping Anesthesia kit/accessories
  • Extended platform at rear for two 5 litre. (Water Cap.) cylinder
  • Large roller bearings 125mm , antistatic castors, for easy mobility and brakes
  • Top tray provided at eye level for keeping monitoring equipment_ Hook for breathing circuit. Wipe clean stainless steel top.
  • Provision to fit ventilator
  • One CO₂ circle absorber system
  • Unitized Rota meter block for oxygen & nitrous oxide with fine adjustment controls & colour coated knob and luminous back plate. Oxygen flow meter calibrated from 100cc/min to 10 litre./ Minute & Nitrous oxide flow meter from 200cc/min to 12 liters/min down Stream receipt of oxygen & (air 0 to 12 litre) (Optional)
  • One vaporizer for Halothane / Isoflurane / Sevoflurane
  • Non return cum blow off valve in circuit ensures that pressure does not hold-up beyond 200 cm. Water column & minimizes risk of back flow of gases.
  • 60 psl outlet for driving ventilator
  • Change over system open circuit or close circuit
  • Emergency Oxygen flush valve at table level to give 35-60 litre/min for emergencies.
  • Cylinder yokes: Pin indexed yokes two each of oxygen & nitrous oxide a 50 mm diameter, colour coded gauges fitted at convenient angle for better visibility & clarity.
  • High efficiency regulators for reliability two each for O₂ & N₂O
  • Vaporizer, Halothane / Isoflurane / Sevoflurane

Anesthesia Workstation Prime Major

Technical Specifications

  • Storage Space: Three spacious drawers to hold essential anesthesia kit and accessories.
  • Castors: Large roller bearing anti-static castors with front brakes.
  • Electronic gas mixing with electronic Hypoxia guard.
  • Audio Visual alarm for failure.
  • Electronic and mechanical Flush 30-70 Lpm Flow.
  • System pressure relief at 125 cm.
  • Cylinder Yokes: Color coded gas specific (pin indexed) yokes with sliding stainless steel clamping bars for easy handling.
  • Holding 1 (One) each for and , 5 Ltr water capacity cylinders.
  • Non-return / Pressure Relief Valve: Minimises risk of back flow of gases, blows off when pressure exceeds 125 cm.
  • Oxygen Flush: Electronic and mechanical flush 30-70 LPM flow.
  • Common Gas Outlet (CGO): Conveniently located CGO with ISO tapers for 22 & 15 mm connections.
  • Pipe Line Gas Inlets: Non-Interchangeable Screw Threaded (NIST) pipeline inlets one each for and Air.
  • I n c a s e o f drop in piped gas pressure the pin index cylinders take over automatically.
  • Hypoxia Guard: Electronic/ Digital Hypoxia guard.
  • Gas Mixing: Electronic flowmeter for the graphical representation of and Air.
  • Selectatec Brackets: Twin Selectatec Block.
  • Breathing Circuits: Bains Circuit & Circle Absorber Y-Circuit provided as standard.