Manually operated ICU bed with Hi-Lo (height adjustment) function
Crank mechanism for backrest, knee rest, and height adjustments
Durable four-section perforated bed platform for ventilation and comfort
Detachable ABS head and foot panels for easy access during emergencies
Collapsible side rails for patient safety and ease of movement
Manual Trendelenburg and reverse Trendelenburg positions available
Smooth-rolling castors with individual brakes for mobility and stability
IV pole provision and drainage hooks included
Sturdy mild steel frame with epoxy powder-coated finish for corrosion resistance
Suitable for ICU, high-dependency units, and hospital wards
Height Adjustment Range (Hi-Lo): 450 mm – 750 mm
Backrest Angle: 0° – 75° (manual crank)
Knee Rest Angle: 0° – 35° (manual crank)
Trendelenburg: 0° – 12° (manual)
Reverse Trendelenburg: 0° – 12° (manual)
Platform Sections: 4-section perforated MS platform
Frame Material:Â steel with epoxy powder coating
Head & Foot Panels: ABS, detachable
Side Rails: Collapsible, aluminum or ABS
Crank System: 3 separate crank handles (backrest, knee rest, Hi-Lo)
Safe Working Load: 200 – 250 kg
Measurement Method: Manual
Measurement Range: 0 – 300 mmHg
Accuracy: ±2 mmHg
Graduation: 2 mmHg increments
Cuff Size: 22 – 42 cm
Bladder Material: Latex or PVC, 2-tube system
Bulb Type: Rubber inflation bulb with chrome-plated release valve
Valve Type: Precision screw-type air control
Mercury Column: Glass tube with metal scale backing
Stand Type: Height-adjustable pole with 5-leg wheeled base
Tubing: Extendable tubing
Unit Height: Adjustable from 900 mm to 1300 mm
Weight: 4.5 – 6 kg
Operating Temperature: 10°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Method: Manual (Aneroid, Auscultatory)
Measurement Range: 0 – 300 mmHg
Accuracy: ±3 mmHg
Cuff Size Range: 22 – 42 cm
Dial Diameter: 50 mm
Manometer Type: Aneroid with 2 mmHg graduation
Bladder Material: Latex or PVC, 2-tube design
Bulb: Rubber inflation bulb with chrome-plated valve
Valve Type: Screw-type precision air release
Stethoscope: Optional, single-head compatible
Weight: 500 g
Operating Temperature: 5°C – 40°C
Storage Temperature: -10°C – 50°C
Measurement Method: Oscillometric
Measurement Range:
– Systolic: 60 – 260 mmHg
– Diastolic: 40 – 199 mmHg
– Pulse Rate: 40 – 180 bpm
Measurement Accuracy:
– Pressure: ±3 mmHg
– Pulse: ±5%
Display Type: LCD/LED digital screen
Memory Capacity: 60 – 120 readings per user
Power Supply:Â batteries or AC adapter
Cuff Size: 22 – 42 cm
Auto Power Off: After 1 minute of inactivity
Weight: 300 – 400 g
Operating Temperature: 5°C – 40°C
Humidity Range: 15% – 85% RH non-condensing
Measurement Parameters:
– SpO₂ (Oxygen Saturation): 0% – 100%
– Pulse Rate: 30 – 250 bpm
SpO₂ Accuracy: ±2% (for 70% – 100% range)
Pulse Rate Accuracy: ±2 bpm or ±2%
Display Type: Large LED or TFT screen
Waveform Display: Plethysmograph (real-time pulse waveform)
Alarm Functions: Adjustable thresholds for SpOâ‚‚ and PR, with sound and visual indicators
Power Supply:
– AC mains (100 – 240V, 50/60 Hz)
– Built-in rechargeable battery
Battery Backup: 4 – 8 hours of operation
Data Storage: Up to 72 hours or more
Connectivity: USB / RS232 / LAN
Weight: ~1.5 – 3 kg
Operating Environment:
– Temperature: 5°C – 40°C
– Humidity: ≤85% non-condensing
©2025-26. All Rights Reserved. Shresha Biortek