Mobile stretcher trolley designed for safe and efficient patient transport
Comes with a high-density waterproof mattress for patient comfort
Strong tubular steel or stainless steel frame construction
Removable stretcher top or fixed depending on model
Foldable/adjustable side rails for patient safety
Four swivel castors for smooth mobility; two with locking brakes
Bumpers on corners for wall and impact protection
Provision for IV pole and oxygen cylinder holder
Easy-to-clean design with corrosion-resistant finish
Suitable for emergency rooms, ICUs, operation theatres, and transport within facilities
Frame Material:Â steel or stainless steel, epoxy powder coated or polished
Top Platform: Mild steel or stainless steel sheet with mattress
Mattress Thickness: 50–75 mm, high-density PU foam with waterproof PVC cover
Side Rails: Collapsible or swing-down, aluminum or stainless steel
Castors: 150 mm diameter, swivel type, 2 with brakes
Load Capacity: 150 – 200 kg
IV Pole: Adjustable, stainless steel
Oxygen Cylinder Holder: Attached or optional
Finish: Epoxy powder coated or stainless steel polished
Height Adjustment Range (Hi-Lo): 450 mm – 750 mm
Backrest Angle: 0° – 75° (manual crank)
Knee Rest Angle: 0° – 35° (manual crank)
Trendelenburg: 0° – 12° (manual)
Reverse Trendelenburg: 0° – 12° (manual)
Platform Sections: 4-section perforated MS platform
Frame Material:Â steel with epoxy powder coating
Head & Foot Panels: ABS, detachable
Side Rails: Collapsible, aluminum or ABS
Crank System: 3 separate crank handles (backrest, knee rest, Hi-Lo)
Safe Working Load: 200 – 250 kg
Measurement Parameters:
– SpO₂ (Oxygen Saturation): 0% – 100%
– Pulse Rate: 30 – 250 bpm
SpO₂ Accuracy: ±2% (for 70% – 100% range)
Pulse Rate Accuracy: ±2 bpm or ±2%
Display Type: Large LED or TFT screen
Waveform Display: Plethysmograph (real-time pulse waveform)
Alarm Functions: Adjustable thresholds for SpOâ‚‚ and PR, with sound and visual indicators
Power Supply:
– AC mains (100 – 240V, 50/60 Hz)
– Built-in rechargeable battery
Battery Backup: 4 – 8 hours of operation
Data Storage: Up to 72 hours or more
Connectivity: USB / RS232 / LAN
Weight: ~1.5 – 3 kg
Operating Environment:
– Temperature: 5°C – 40°C
– Humidity: ≤85% non-condensing
Light Source: LED or Halogen
Color Temperature: Approx. 5500K – 6500K (cool white)
Illumination Intensity: Up to 40,000–100,000 lux
Weight: Typically under 400 grams
Operating Time: Depends on intensity setting
Spot Size: Adjustable
Material: High-grade plastic and metal components
Power Supply: AC adapter or battery pack
Usage Duration of Light Source: Up to 50,000 hours
Technical Specifications