Features:
Provides intensive phototherapy from both above and below the infant for effective bilirubin reduction
Equipped with compact fluorescent lamps (CFL) that emit blue light in the therapeutic wavelength range
Double surface exposure enhances treatment efficiency and reduces therapy time
Height-adjustable upper light source for optimal positioning
Integrated baby cradle or transparent acrylic bassinet allows maximum light penetration
Digital hour meter or timer to track therapy duration
Ventilation slots and heat management features to prevent overheating
Mounted on wheels with locking system for easy mobility and stability
Specifications:
Light source: Compact Fluorescent Lamps (CFL), blue light (wavelength ~420–480 nm)
Number of lamps: typically 6–8 on top and 4–6 at the base
Irradiance: ≥ 30–40 µW/cm²/nm (varies by model)
Cradle size: Suitable for standard neonatal dimensions
Power supply: 220–240 V, 50/60 Hz
Height adjustment range: ~100–150 mm
Structure: Powder-coated metal or stainless steel frame
Controls: On/off switches, timers, optional intensity control
Height Adjustment Range (Hi-Lo): 450 mm – 750 mm
Backrest Angle: 0° – 75° (manual crank)
Knee Rest Angle: 0° – 35° (manual crank)
Trendelenburg: 0° – 12° (manual)
Reverse Trendelenburg: 0° – 12° (manual)
Platform Sections: 4-section perforated MS platform
Frame Material: CRCA steel with epoxy powder coating
Head & Foot Panels: ABS, detachable
Side Rails: Collapsible, aluminum or ABS
Crank System: 3 separate crank handles (backrest, knee rest, Hi-Lo)
Safe Working Load: 200 – 250 kg
Measurement Method: Oscillometric
Measurement Range:
– Systolic: 60 – 260 mmHg
– Diastolic: 40 – 199 mmHg
– Pulse Rate: 40 – 180 bpm
Measurement Accuracy:
– Pressure: ±3 mmHg
– Pulse: ±5%
Display Type: LCD/LED digital screen
Memory Capacity: 60 – 120 readings per user
Power Supply:Â batteries or AC adapter
Cuff Size: 22 – 42 cm
Auto Power Off: After 1 minute of inactivity
Weight: 300 – 400 g
Operating Temperature: 5°C – 40°C
Humidity Range: 15% – 85% RH non-condensing
Measurement Parameters:
– SpO₂ (Oxygen Saturation): 0% – 100%
– Pulse Rate: 30 – 250 bpm
SpO₂ Accuracy: ±2% (for 70% – 100% range)
Pulse Rate Accuracy: ±2 bpm or ±2%
Display Type: Large LED or TFT screen
Waveform Display: Plethysmograph (real-time pulse waveform)
Alarm Functions: Adjustable thresholds for SpOâ‚‚ and PR, with sound and visual indicators
Power Supply:
– AC mains (100 – 240V, 50/60 Hz)
– Built-in rechargeable battery
Battery Backup: 4 – 8 hours of operation
Data Storage: Up to 72 hours or more
Connectivity: USB / RS232 / LAN
Weight: ~1.5 – 3 kg
Operating Environment:
– Temperature: 5°C – 40°C
– Humidity: ≤85% non-condensing
©2025-26. All Rights Reserved. Shresha Biortek PVT LTD