Features:
Based on immunoturbidimetry and immunonephelometry principles
Compatible with venous blood, peripheral plasma, serum, urine, and CSF samples
Onboard data storage capability
Inbuilt thermal printer for direct patient report printing
Touchscreen interface with stylus support for user-friendly operation
Daily and monthly 3-level Quality Control with Levey-Jennings (LJ) graph support
Software connectivity via RS-232 port for data transfer to computer systems
Accurate linkage pipettor for automated and reliable pipetting of sample, reagent, and diluent
Lot-specific master calibration curves included with every kit to reduce calibration cost and avoid inter-lot calibration errors
CE certified and DGS&D approved
5-year warranty with Comprehensive Maintenance Contract (CMC)
Specifications:
Sample types: Venous blood, plasma, serum, urine, cerebrospinal fluid
Operating temperature: 10°C to 30°C
Operating humidity: Up to 90%
Repeatability: Coefficient of Variation (CV) <4%
Voltage requirement: AC 220V ±5%
Connectivity: RS-232 port for computer interfacing
Printer: Inbuilt thermal printer for report output
SPECIFICATIONS:
Temperature range | -10° C to -40°C |
---|---|
Temperature accuracy | ±0.5°C |
Temperature Uniformity | ±0.1°C |
Temperature controller | Dual display PID controller |
Temperature sensor | PT100 |
Inner chamber | SS 304 |
External cabinet | Powder coated GI sheet |
Insulation | Glass wool |
Door | Insulated door Mechanical latch / clamp |
Heaters | Resistance wire heaters |
Shelves | SS wire mesh (removable) |
Standard fittings | Mains on/off switch Load Indicator Fan on/off switch |
Power supply | 220 Volts 50Hz |
Optional | GMP construction (Inner & outer SS304) PLC + HMI controller w/ USB interface 21 CFR Part 11software Data logger w/ USB interface Thermal printer Inner chamber LED light |
SPECIFICATIONS:
Temperature Range | 5°C to 60°C |
Temperature accuracy | ±1°C |
Temperature controller |
|
Humidity Range | 40% to 95% RH |
Humidity accuracy | ±3% RH |
Humidity controller |
|
Chamber Illumination | Fluorescent white light |
Construction | Double walled |
Insulation | PUF insulation |
Exterior | Powder coated GI sheet |
Interior | Stainless steel 304 |
Door | Solid insulated door with lock and key |
Inner door | Glass door fitted in steel frame |
Shelves / trays | 2 to 5 steel wire mesh trays (height adjustable) |
Air Circulation | Axial fan / blower |
Refrigeration | CFC Free compressor with condenser, motor and relay complete unit |
Humidity system |
|
Optional |
|
Volume (Liters) | Inner Chamber size (mm) | Trays | |
200 Liters | 600 x 600 x 600 | 2 | |
324 Liters | 600 x 600 x 900 | 2 | |
450 Liters | 600 x 600 x 1250 | 3 | |
600 Liters | 600 x 800 x 1250 | 3 | |
800 Liters | 800 x 800 x 1250 | 4 | |
1000 Liters | 800 x 800 x 1570 | 4 |
Shaker Speed | (20 – 250 RPM) (350,400 & 500 OPTIONAL) |
---|---|
Orbit Dia | ø 25 mm |
Accuracy | ± 2% of maximum speed |
Temperature range | 5˚C above RT to 60˚C & with cooling 5°C-60°C (Customize temperature options available) |
Resolution | 0.1°C |
Temp. accuracy | ± 0.3 ̊C |
Power supply | 230V ± 10%, 50Hz |