AUTOCLAVES & STERILISATIONS

Product Categories

TABLE TOP FRONT LOADING

Advantages:

  • Sterilizing, exhaust of water & steam drying are fully automatic.
  • Requires a sterilizing time of just 7 minutes at 134°C (instead of 20 minutes at 121°C).
  • A totally hassle and tension free sterilizer which can even be kept inside an operation theatre.
  • Results reproducible because full cycle is automatic, requiring no human intervention.
  • Single lever pronged closure system with patented Silicone Gasket (registered design No. 208774.)
  • µP Controller with following parameters programmable by user: Sterilizer Time: up to 99 minutes. Sterilizing Temperature: up to 134°C. Drying time: up to 99 minutes.
  • Valves for water filing and exhaust.
  • Drying with door open facility.

 

 

 

Model Capacity Inner Dimensions Tray Gross Dimension / Weight
DR T2FL AC01 16 L  230 x 400 mm 2 trays 870 x 840 x 740 mm / 81.4 kg
DR T2FL AC02 22 L  250 x 450 mm 3 trays 840 x 810 x 740 mm / 81.4 kg

 

 

Model Working Chamber
Size / Capacity
DR T2FL AC A1 300 x 500 mm / 35 L
DR T2FL AC A2 400 x 600mm / 75 L

PLASMA STERILIZER

Specifications:

MODEL DR HPS LC50 DR HPS LC 110 DR HPS LC135 DR HPS 16053
Chamber volume 50 Ltr. 110 Ltr. 135 Ltr. 160 Ltr.

INSTRUMENT STERILIZER

INSTRUMENT STERILIZER, TABLE MODEL, S.S.

CODE
APPROX. CAPACITY
DIMENSIONS (LxBxH)
TRAY DIMENSIONS (LxBxH)
DR ACS IS01 
5.5 Lit.
300 x 150 x 125mm
245 x 125 x 25mm
DR ACS IS02
12.0 Lit.
430 x 200 x 150mm
355 x 180 x 25mm
DR ACS IS03
15.0 Ut.
510 x 200 x 150mm
435 x 180 x 25mm

 

INSTRUMENT STERILIZER, NON-ELECTRIC, ECONOMY

CODE
APPROX. CAPACITY
DIMENSIONS (LxBxH)
DR ACS IS NEE01
2.0 Lit
200 x 125 x 80mm
DR ACS IS NEE02
2.5 Lit.
250 x 125 x 80mm
DR ACS IS NEE03
4.5 Lit.
300 x 150 x 100mm
DR ACS IS NEE04
5.2 Lit.
350 x 150 x 100mm
DR ACS IS NEE05
6.0 Lit.
400 x 150 x 100mm
DR ACS IS NEE06
12.0 Lit.
400 x 200 x 150mm
DR ACS IS NEE07
13.5 Lit.
450 x 200 x 150mm
DR ACS IS NEE08
15.0 Lit.
500 x 200 x 150mm

 

INSTRUMENT STERILIZER, ELECTRIC, ECONOMY

CODE
APPROX. CAPACITY
DIMENSIONS (LxBxH)
DR ACS IS EE01
2.7 Lit.
200 x 125 x 115mm
DR ACS IS EE02
3.5 Lit.
250 x 125 x 115mm
DR ACS IS EE03
6.2 Lit.
300 x 150 x 140mm
DR ACS IS EE04
7.2 Lit.
350 x 150 x 140mm
DR ACS IS EE05
8.0 Lit.
400 x 150 x 140mm
DR ACS IS EE06
17.0 Lit.
450 x 200 x 190mm
DR ACS IS EE07
19.0 Lit.
500 x 200 x 190mm

 

 

INSTRUMENT STERILIZER, ELECTRIC, THERMOSTAT, ECONOMY

 

CODE
APPROX. CAPACITY
DIMENSIONS (LxBxH)
DR ACS IS ETE01
6.0 Lit.
300 x 150 x 140mm
DR ACS IS ETE02
7.0 Lit.
350 x 150 x 140mm
DR ACS IS ETE03
8.0 Lit.
400 x 150 x 140mm
DR ACS IS ETE04
17.0 Lit.
450 x 200 x 190mm
DR ACS IS ETE05
19.0 Lit.
500 x 200 x 190mm

DENTAL AUTOCLAVE

 

Model Chamber Size External Dimension in mm Trays Gross Dimension / Weight
DR ACS DA 01 250 mm x 450 mm 500 x 650 x 430 3 770 x 570 x 520 mm / 54 kg

 

Model Chamber Size External Dimension in mm Gross Dimension / Weight
DR ACS DA B01 310 x 600 580 x 730 x 655 630 x 815 x 725 mm / 115 kg

VERTICAL AUTOCLAVE

S.NO.
MODEL
DESCRIPTION
CHAMBER SIZE (MM)
CHAMBER VOLUME
1 DR VAC HM 3WD75 Vertical, Triple Walled, Basic with Drying System 400 Dia x 600 H 75 Ltr
2 DR VAC HM 2W75 Vertical, Double Walled, Basic 400 Dia x 600 H 75 Ltr
3 DR VAC HM 2W35 Vertical, Double Walled, Basic 300 Dia x 500 H 35 Ltr

 

 

S.NO.
MODEL
DESCRIPTION
CHAMBER SIZE (MM)
CHAMBER VOLUME
1 DR VAC HM 3WST75 Vertical, High Pressure, Triple Walled, Steam Storage with PLC Controlled Temperature, Low Water Cut-off, Timer,Alarm 400 Dia x 600 H 75 Ltr
2 DR VAC HM 3WS75 Vertical, High Pressure, Triple Walled, Steam Storage with PLC Controlled Temperature, Low Water Cut-off 400 Dia x 600 H 75 Ltr

HORIZONTAL AUTOCLAVE

Model DR 42M HAC 234U DR 42M HAC 432U DR 42M HAC 540U DR 42M HAC 648U DR 42M HAC 864U
DR 42M HAC 234T DR 42M HAC 432T DR 42M HAC 540T DR 42M HAC 648T DR 42M HAC 864T
Capacity (L) 324 432 540 648 864
Chamber Dim (mm) 600 x 600 x 900 600 x 600 x 1200 600 x 600 x 1500 600 x 900 x 1200 600 x 900 x 1600
Door Single Door – for models ending with ‘U’

Double Door – for models ending with ‘T’

Max Operating Parameters 206.8 kPA (30 psi) / 135˚C / Vacuum

CYLINDRICAL STEAM STERILISER

S.NO.
MODEL
DESCRIPTION
CHAMBER SIZE (MM)
CHAMBER VOLUME
1 DR M4 CAC S150 Horizontal Cylindrical Automatic Single Door 400 Dia x 1200 L 150 Ltr
2 DR M4 CAC D150 Horizontal Cylindrical Automatic Double Door 400 Dia x 1200 L 150 Ltr
3 DR M4 CAC S175 Horizontal Cylindrical Automatic Single Door 500 Dia x 900 L 175 Ltr
4 DR M4 CAC D175 Horizontal Cylindrical Automatic Double Door 500 Dia x 900 L 175 Ltr
5 DR M4 CAC S235 Horizontal Cylindrical Automatic Single Door 500 Dia x 1200 L 235 Ltr
6 DR M4 CAC D235 Horizontal Cylindrical Automatic Double Door 500 Dia x 1200 L 235 Ltr
7 DR M4 CAC S340 Horizontal Cylindrical Automatic Single Door 600 Dia x 1200 L 340 Ltr

Sterilizer Electric

Model No: DR-STZ-SS
Type of Product: Instrument Sterilizer
Size: 30.48×20.32×15.24 cm
Material: Stainless Steel
Application: Hospital, Laboratory, Clinics
Power: 2KW
Voltage: 220 v
Color: Silver

RECTANGULAR AUTOCLAVE

Construction Economy Model Double Walled Model Triple Walled Model
MOC Exterior Painted MS sheet SS 304 (mirror finish) SS 304 (mirror finish)
No. of walls Two Two Three
Lid Polished MS SS 304 SS 304
Interior SS 304 with silicon gasket
Working Pressure 15-30 psi
Working Temp. 121°C to 134°C
Controller Auto set to 15psi & 121°C
Pressure display Analogue dial gauge
Timer Mechanical timer
Programmable Programmable automatic start timer
Hydraulic tested Hydraulically Tested up to 40 psi (ASME Guideline)
Lick lock Single hand easy lock system for operating and closing
Program for heating sterilization, exhaust, warming and completion.
Basket Stainless steel basket Stainless steel basket Not Required
Power supply 220 Volts 50Hz
Standard Fittings Low water indicator; Automatic pressure switch; Pedal lifting device Steam release valve; Water outlet valve; Spring loaded safety valve Power cable with three pin tops
Optional Accessories
  • Fully stainless steel construction (GMP)
  • Up to 134°C temperature range
  • PID temperature controller cum timer with alarm (buzzer)
  • PLC with HMI interface with data logging
  • 21 CFR Part 11 software
  • Thermal Printer
  • Lower water cut-off

DIGITAL WATER BATH

TECHNICAL PARAMETERS:

Parameter DR-04WB DR-06WB
Column 2 rows 4 holes 2 rows 6 holes
Temp. range Rt+5~100℃
Temp. Resolution Ratio 0.1℃
Temp. Motion ±0.5℃
Temp. Uniformity ±1℃
Water sink Stainless steel, surface electrolysis treatment
Outer shell Cold rolled steel plate, surface electrostatic powder spray.
Heater Stainless steel U-type heating tube
Power rating 1200 W
Temp. control mode PID Controller
Timer 0 – 999 min(with timing function)
Timing function Timing function, auto stop feature
Program Optional: multi-section program control
Additional function Deviation correction, menu key lock, power failure back-up, power-off parameter memory, PID-Tunable control
Sensor Thermal resistor
Safety device Over-temperature alarm, short-circuit protection.
Inner Chamber size(W*L*H) 305 x 305 x 130 mm 305 x 470 x 130 mm
Packing size (W*L*H) 415 x 415 x 275 mm 400 x 560 x 250 mm
Internal volume 12 L 18.6 L
Cover number per hole ∅120 mm
Power Supply 50/60Hz 220V, 50/60 Hz
Weight 6.5 kg 8 kg

LOOP STERILIZER

SPECIFICATIONS:

Model No. DR-800D
Center Max. Temp. 825°C
Low Level Temp. 480°C
Heating Speed 20min (to max. temp.)
Max. Sterilize Diameter Φ35mm
Heating Element Length 100mm
Adjustable Angle 75°~120°
Voltage AC 220V / AC 110V, 50/60Hz
Power 400W
Fuse 250V, 3A/5A, Ф5×20
Dimension (WxDxH) 92 x 101 x 170mm
Net Weight 1.1kg