Features:
Inner chamber made of high-quality AISI-304 stainless steel
Outer cabinet made from powder-coated CRCA sheet
High-grade CFC-free PUF insulation (70 mm for cabinet, 80 mm for door)
Heavy-duty telescopic channels for smooth, full-load drawer movement
Lockable heavy-duty swivel castor wheels for easy mobility
Ergonomically designed handle with integrated door lock
Outer door with see-through double-pane glass window
Internal acrylic drawer covers to minimize temperature loss
Flicker-free internal LED lighting activates on door opening
Wide LCD display for real-time and 24-hour temperature monitoring
Audio-visual alarms for temperature deviations, sensor faults, and door open
Visual indicators for power and compressor status
User-settable parameters for temperature, alarm thresholds, and buzzer delay
Auto defrost system for maintenance-free operation
Dual temperature sensors: simulated blood and chamber ambient
Forced air circulation via dual motorized blower fans for uniform cooling
Battery backup (6–8 hrs) for alarms, display, and chart recorder
Self-diagnosis function with real-time error display
Safety thermostat to prevent freezing/negative temperatures
Low-noise operation under 85 dB(A)
CE marked / USFDA compliant from ISO 13485 certified manufacturer
Supplied with line voltage corrector of appropriate rating
Specifications:
Operating temperature range: 2°C to 8°C
Internal volume: 400 liters (approx.)
Temperature alarm range: configurable for 2°C–8°C
High/low temperature alarm activation beyond 2°C–8°C limits
Dual temperature sensors (simulated load and ambient)
Visual and audio alarms for over/under temperature, door open, sensor error
Compressor control based on actual blood temperature
LCD screen displays real-time temperature, alarms, and 24-hour history
Chart recorder support with battery backup
Castor wheels: lockable and heavy-duty
Door: see-through double-glass with lock and insulated construction
Insulation: 70 mm cabinet, 80 mm door (CFC-free PUF)
Error self-diagnosis and display system
Voltage: standard 220V ±20V, 50Hz supply
Construction: inner AISI-304 SS, outer powder-coated CRCA
Safety features: thermostat, compressor overrun indicator, error alarms
SPECIFICATIONS:
| Temperature range | -10° C to -40°C |
|---|---|
| Temperature accuracy | ±0.5°C |
| Temperature Uniformity | ±0.1°C |
| Temperature controller | Dual display PID controller |
| Temperature sensor | PT100 |
| Inner chamber | SS 304 |
| External cabinet | Powder coated GI sheet |
| Insulation | Glass wool |
| Door | Insulated door Mechanical latch / clamp |
| Heaters | Resistance wire heaters |
| Shelves | SS wire mesh (removable) |
| Standard fittings | Mains on/off switch Load Indicator Fan on/off switch |
| Power supply | 220 Volts 50Hz |
| Optional | GMP construction (Inner & outer SS304) PLC + HMI controller w/ USB interface 21 CFR Part 11software Data logger w/ USB interface Thermal printer Inner chamber LED light |
TECHNICAL PARAMETERS
Volume [L]: 220
Temp. Range [°C]: +5 to 60
Temp. Resolution [°C]: 0.1
Temp. Fluctuation at 37°C [°C]: ±0.5
Temp. Uniformity at 37°C [°C]: ±1
Rotation Rate [rpm]: 1~300
Rotation Accuracy [rpm]: ±1
Vibration Amplitude [mm]: Ø25
Timer Range [h]: 0~999
Number of Trays [pc]: 1 included ( 2 optional)
Power Supply [V, Hz]: 220, 50/60
Internal Dimensions W×D×H [mm]: 600x600x600
Housing Dimensions W×D×H [mm]: 755×870×1310
Tray Size W×D [mm]: 595x595mm
Standard Configuration [pcxml]: 16×250/500 or 9×1000 ml or 4×2000 ml
Net Weight [kg]: 220
| Item Name | CO2 Incubator | |||||
| Model No. | DR-CO2-80UV | DR-CO2-80 | DR-CO2-80+ | DR-CO2-180UV | DR-CO2-180 | DR-CO2-180+ |
| Sterilization | UV | 140°C | 180°C | UV | 140°C | 180°C |
| Volume | 80L | 80L | 80L | 180L | 180L | 180L |
| Microprocessor-based controller | Proprietary algorithm to control CO2 and temperature | |||||
| Display | LCD touch display | |||||
| Temp control range | Ambient +5°C- 60°C | |||||
| Temp stability | ±0.1°C | |||||
| Temp field uniformity | ±0.3°C (at 37°C ) | |||||
| Timer function | 0 – 999hr 59 min. | |||||
| CO2 measurement principle | Infrared (IR) detection | |||||
| CO2 control range | 0-20% | |||||
| CO2 display resolution | 0.10% | |||||
| CO2 supply | 0.05~0.1MPa is recommended | |||||
| Relative Humidity | Ambient humidity ~95% at 37°C | |||||
| HEPA filtration | HEPA filters at the gas inlet, ISO 5 level, 5 minutes | |||||
| Temperature recovery time | ≤10 min (open door 30sec room temperature 25°C set value 37°C) | |||||
| O2 concentration recovery time | ≤5 min (open the door 30sec set value 5%) | |||||
| MOC | The inner chamber is made up of stainless steel and outer chamber with MS with powder coating | |||||
| Light | Florescent light | |||||
| Historical data storage | 250,000 messages | |||||
| Data export interface | USB interface | |||||
| Scalability | Up to 2 units can be stacked. | |||||
| Working environment temperature | 18~30°C | |||||
| Power supply | 230V±10%, 50~60Hz | |||||
| Inner Dimensions (L x D x H) mm | 450x450x450 | 550x600x600 | ||||
| Outer Dimensions (L x D x H) mm | 650x650x750 | 750x800x850 | ||||
©2025-26. All Rights Reserved. Shresha Biortek PVT LTD