Measurement principle: Oscillometric method
Measured parameters: Systolic blood pressure, diastolic blood pressure, and heart rate (pulse)
Device design: Cuffless and wearable, engineered for continuous and comfortable use
Display: Built-in screen provides immediate and clear result visualization
Communication interface: Bluetooth enabled for wireless connection to mobile devices
Data compatibility: Syncs with a smartphone app for real-time health data management and review
Monitoring capability: Suitable for both daytime and nighttime blood pressure tracking
Power source: Rechargeable lithium battery system ensures extended usage and reusability
Charging method: USB-compatible charging port (exact details not specified in brochure)
Operating environment: Designed for use in home, outpatient, and ambulatory care settings
Application environment: Intended for individual users needing ongoing blood pressure monitoring
Wear duration: Designed to remain comfortable for extended wear throughout daily routines
Storage and review: Historical data storage available through app for long-term trend analysis
Maintenance: Low-maintenance design with digital tracking reducing the need for physical logbooks
5-part WBC differential (WBC 5-DIFF)
29 reportable parameters
Sample type: Whole blood and pre-diluted
Throughput: 60 samples per hour
Display: Touch screen operation
Graphical output: Histogram and scattergram for WBC, RBC, and PLT
Built-in thermal printer included
Sample access: Open vial mode
Storage: Up to 100,000 results with histograms and scattergrams
Barcode scanner: Optional
External printer: Optional
Automatic clog removal system
LIS connectivity supported
User interface: Multilingual support
Specifications:
29 reportable parameters including 5-part white blood cell differential
Processes up to 60 samples per hour
Sample modes include whole blood and pre-diluted samples
Operated via a touchscreen interface
Displays histograms and scattergrams for WBC, RBC, and PLT
Includes built-in thermal printer
Built-in barcode scanner included
Supports external printer (optional)
Equipped with automatic clog removal functionality
LIS connectivity supported
Multilingual user interface
Designed for routine use in clinical laboratories
Measures five electrolyte parameters: Sodium (Na⁺), Potassium (K⁺), Chloride (Cl⁻), Calcium (Ca²⁺), and Lithium (Li⁺)
Uses ion-selective electrode (ISE) technology for accurate and stable measurement
Compatible with multiple sample types: serum, plasma, whole blood, and urine
Features automatic sample aspiration for consistent and hands-free operation
Operated via a touchscreen interface for easy navigation and control
Includes built-in thermal printer for immediate printout of test results
Compact and lightweight design optimized for limited bench space
Suitable for clinical laboratories, diagnostic centers, and hospital departments
Designed for both routine and urgent testing scenarios
Requires minimal maintenance, reducing downtime and user intervention
Delivers fast results, supporting quick clinical decision-making
Low reagent consumption enables cost-effective daily operation
Provides reliable long-term performance in busy laboratory environments
WBC Classification: 3-part differential (Lymphocytes, Monocytes, Granulocytes)
Reportable Parameters: 22 hematology parameters
Sample Mode: Open vial sampling
Throughput: Processes up to 60 samples per hour
Display: 8.4-inch TFT color LCD with responsive touch screen functionality
Result Storage: Up to 100,000 patient records, including corresponding histograms
Printer: Built-in thermal printer for immediate result output
Connectivity: LIS-supported for hospital/lab system integration
Optional Accessories: Barcode scanner and external printer (available on request)
User Interface: Multilingual support for international usability
Reagent System: Low reagent consumption design for economical daily use
Reportable parameters: 29
Sample mode: Whole blood and pre-diluted
Throughput: 60 samples per hour
Display: 10.4″ TFT touch screen
Storage: 50,000 results with histograms and scattergrams
Printer: Built-in thermal printer
Connectivity: LIS supported
Optional: Barcode scanner and external printer
Automatic maintenance: Clog removal
Interface: User-friendly with multilingual support
Reagent system: Low consumption
Sample type: Whole blood
Sample volume: 100 μL
Test time: Approximately 2 minutes
Parameters available (depending on cartridge):
Blood gases: pH, pCO₂, pO₂
Electrolytes: K⁺, Na⁺, Cl⁻, Ca²⁺
Metabolites: Glucose, Lactate
Hematology: Hematocrit
Measurement method: Cartridge-based, pre-calibrated disposable system
Display: Built-in touchscreen
Printing: Built-in thermal printer
Power: Rechargeable battery and AC adapter support
Data connectivity: Yes (connects to hospital systems/data management platforms)
System type: Portable, point-of-care blood gas and chemistry analyzer
Photometric system: Flow cell with quartz cuvette, 30 µL volume
Light source: Long-life halogen lamp
Wavelengths: 340nm, 405nm, 492nm, 505nm, 546nm, 578nm, 620nm, 670nm
Measurement methods: End-point, fixed-time, and kinetic
Temperature control: 37°C ± 0.1°C
Reading time: Adjustable depending on test protocol
Sample volume: Typically 2–20 µL depending on method
Display: High-resolution color LCD touch screen
Storage: Can store up to 200 test programs and 1000 results
Printer: Built-in thermal printer for result printing
Interfaces: USB ports for keyboard/mouse/printer; RS232 for data transfer
Power supply: AC 100–240V, 50/60Hz
Operating environment: Temperature 10–30°C, humidity ≤85%
Dimensions and weight: Compact footprint suitable for lab benches
3-part differential of white blood cells (WBCs)
Measures 21 parameters including WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, and others
Throughput: up to 60 tests per hour
Sample volume requirement: Low volume for both whole blood and pre-diluted samples
Display: High-resolution touchscreen
Built-in thermal printer for immediate results
Storage: Internal memory for thousands of patient results
Data export via USB and support for LIS connectivity
Calibration and QC functions included
Power supply: Standard AC with stable internal operation
Operates in temperature- and humidity-controlled environments typically found in clinical labs
Reagents: Operates with dedicated low-volume reagent sets
Interfaces: USB and serial ports for peripherals and data sharing
Noise and vibration-minimized internal mechanics for steady performance
1-channel ECG acquisition
12-lead ECG recording with lead switching
Built-in thermal printer for real-time ECG output
Prints on 50mm wide paper
Operates on AC power with internal battery backup
Simple display and keypad for essential control
Measurement of basic ECG parameters (heart rate, intervals)
Basic filtering system for noise reduction
Limited internal memory for recent ECG recordings
Compact form factor designed for handheld use
Patient safety protections including input isolation
Complies with standard medical equipment regulations
3-channel simultaneous ECG acquisition
12-lead ECG recording
Integrated thermal printer for ECG report generation
Prints on 80mm wide paper
Built-in rechargeable battery with AC power operation
LCD display with functional navigation keys
Standard measurements: heart rate, PR/QRS/QT intervals, axes
Noise filters: baseline, muscle, AC interference
USB or SD card support for data export (model dependent)
Complies with medical safety and electromagnetic standards
Patient isolation and overvoltage protection included
Memory for limited number of ECG records
Specifications
12-channel electrocardiograph system
8-inch high-resolution color touchscreen display
Alphanumeric keyboard for data input
Internal memory capacity for storing up to 800 ECG records
USB flash drive support for storage expansion and data export
Built-in thermal printer supporting standard thermal and A4 fax paper
USB connectivity for external printer support
Data communication via LAN and optional internal Wi-Fi
Export formats supported: PDF, SCP, FDA-XML, DICOM
Supports standard communication protocols: DICOM Worklist, HL7, GDT
24-bit analog-to-digital conversion for precise signal detection
Common-mode rejection ratio (CMRR) greater than 140dB
Real-time ECG waveform freezing and review up to 120 seconds
Automatic measurement and interpretation validated with CSE, AHA, and MIT databases
Built-in Glasgow interpretation algorithm
Optional vector ECG analysis feature
Compatible with optional SE-1515 data management software and Smart ECG Viewer
Rolling stand or trolley configuration available
Basic model variant offered for simplified applications
Specifications:
Sample types: Venous blood, plasma, serum, urine, cerebrospinal fluid
Operating temperature: 10°C to 30°C
Operating humidity: Up to 90%
Repeatability: Coefficient of Variation (CV) <4%
Voltage requirement: AC 220V ±5%
Connectivity: RS-232 port for computer interfacing
Printer: Inbuilt thermal printer for report output
Specifications:
Operating temperature range: 2°C to 8°C
Internal volume: 400 liters (approx.)
Temperature alarm range: configurable for 2°C–8°C
High/low temperature alarm activation beyond 2°C–8°C limits
Dual temperature sensors (simulated load and ambient)
Visual and audio alarms for over/under temperature, door open, sensor error
Compressor control based on actual blood temperature
LCD screen displays real-time temperature, alarms, and 24-hour history
Chart recorder support with battery backup
Castor wheels: lockable and heavy-duty
Door: see-through double-glass with lock and insulated construction
Insulation: 70 mm cabinet, 80 mm door (CFC-free PUF)
Error self-diagnosis and display system
Voltage: standard 220V ±20V, 50Hz supply
Construction: inner AISI-304 SS, outer powder-coated CRCA
Safety features: thermostat, compressor overrun indicator, error alarms
| Model | DR-SP-350 | Absorbance accuracy |
±1% (7.332Abs at 260nm) |
|
| 4 Light Source | 0.02mm 0.05mm 0.2mm 1.0mm | Spectral resolution | <1nm | |
| Photometric accuracy | ±0.005A or ±1% | |||
| Detectors | HAMAMATSU UV Enhanced CMOS Line Array Sensing | Wavelength accuracy | ±1nm within | |
| Nucleic acid/ protein assay range | 0-27,500 ng/µl dsDNA
0.06-820 mg/mL BSA |
Wavelength Reproducibility | <±0.2nm | |
| Sample wavelength scanning | 190-850nm | |||
| Fluorescence sensitivity | DsDNA: 0.5pg/ul | Base measurement only | 0.5~2ul | |
| Fluorescence linearity | ≤1.5% | Sample base material | Quartz fiber and stainless steel | |
| Wavelength range | (190nm-850nm) | Testing time | <5S | |
| Sample volume requirements | 0.5-2ul | Power consumption at standby | 5W | |
| OD600 absorbance range | 0-6.000Abs | Data output method | USB | |
| OD600Absorbance stability | [0,3)≤0.5%,[3,4)<2% | Light source | Xenon flashing light | |
| OD600Absorbance accuracy | [0,2)≤0.005A,[2,3)≤1%,[3,4)≤2% | Power adapter | 24V DC | |
| Od600 Repeatability of absorbance |
[0,3)≤0.5%, [3,4)<2% |
Power consumption |
25W |
|
| Absorbance range | 0.02-300A (Equivalent to 10mm) | Dimension | W200mm×D260mm×H165mm | |
| Absorbance | 0.002Abs (0.2mm optical range) | Weight | 5Kg | |

Dr Labs pH-030 New Arrival with Precision Glass Bulb Electrode Portable PH Meter Liquid PH Alkalinity Value Digital Water Purity Tester Hydro tester Pen with Care Box & Calibration Screw Driver Suitable for Household RO Water Purifiers Filters, Drinking Water, Swimming Pools, Spas, Food, Drink, Gardening, Aquariums, Hydroponics A pH meter, also called a sensor or tester, is a device used to measure the alkalinity of a substance with a single-line LCD screen, a replaceable electrode, and a low power demand. A pH meter used to measure the pH of substance such as water, food, beer, or wine in laboratory, industrial, and food applications.
3-In-1 Digital TDS meter provides accurate readings for TDS (Total Dissolved Solids) EC (Electrical Conductivity) and temperature. Professional, Accurate, and Precise 3-in-1 TDS, EC, and Water Temperature Meter. The TDS meter has automatic temperature compensation in measurement mode. 9 minutes no operation, the meter will automatically shut down. Save power, extend battery life.
SALIENT FEATURES:
• Large back light LCD display shows mode indicator,
ph value, temperature
•Up to 3 point push -button calibration with
automatic buffer recognition
•Selectable pH buffer standards and temperature units.
•Automatically calculates and display electrode slope
after calibration
•Automatic temperature compensation (ATC) ensure
highly accurate measurements over the entire range.
•Automatic endpoint function freezes the stable
measured value
•Setup menu allows setting the pH buffer group,
number of calibration points, temperature unit,
auto-power off, etc.
•Reset function can resumes all setting to factory
default value
Dr Labs DR-PH-100 is an easy-to-use benchtop pH meter designed for daily testing and quality control.
This meter has a clear and bright back light LCD display that show the measured pH value, temperature,
mode indicators.
| Model | DR-PG-300 | DR-PG-500 |
|---|---|---|
| Make | DR Labs | DR Labs |
| Capacity | 300 g | 500 g |
| Readability (d) | 0.001g (1mg) | 0.001g (1mg) |
| Repeatability | 0.001 g | 0.001 g |
| Linearity | 0.002 g | 0.002 g |
| Pan Size | Ø 90 mm | Ø 90 mm |
| Response Time | 3 – 4 sec | 3 – 4 sec |
| Calibration | External | External |
| Display | Backlight LCD | Backlight LCD |
| Tara Range | Full | Full |
| Operating emperature | 10 to 40°C | 10 to 40°C |
| Power supply | AC 220V / 50Hz | AC 220V / 50Hz |
| Dimension | 325 x 300 x 225 | 325 x 300 x 225 |
| Weight | 4kg | 4kg |
Digital Portable Baby Weighing Scale/Weight Machine with Baby Tray (NEW MODEL) FEATURES: *Multi-Function Baby Weighing Scale with Min. Capacity of 10g & Max. Capacity of 100kg. *Equipped with a high precision “Stain-Gauge” Sensor and High Capability CPU to ensure Weight Accuracy. *Designed For Comfort The Smart Weigh Digital Baby Scale Is Beautifully Designed To Ensure The Comfort Of Your Baby. *TARE Feature i.e. Weigh the baby on a blanket or towel and press tare button to get the Baby Weight without any added weight. *Dual Usage Support i.e. Remove the Baby Tray and it can be used as a normal weighing scale. *Keep Track of Your Baby’s Weight To Make Sure Your Baby Is Getting The Proper Nutrition And Is Being Fed The Correct Amount.
| Brand |
|
| Model Number |
|
| Type |
|
| Measurement Depth |
|
| Meter Type |
|
| Accuracy |
|
| Functions |
|
| Suitable For |
|
| Model Name |
|
| Measurement Range |
|
| Model | DR-HMS-5LC |
|---|---|
| Make | DR Labs |
| Display | LCD |
| Max. Volume (ml) | 5000 |
| Speed (RPM) | 200-2000 RPM |
| Minimum Resolution (RPM) | 100 RPM |
| Top Plate Size | 190 x 190 mm |
| Plate Material | Ceramic |
| Max. Temp. (Plate surface) | 300°C |
| Temp. Sensor | PT100 |
| Temp. Controller | PID |
| Temp. Resolution | 0.1°C |
| Temp. Accuracy | ±0.5°C ( <100°C) ± 1° C (<300°C) |
| Timer | Yes |
| Power Wattage | Heating: 600 W, Stirring: 20 W |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 300 x 190 x 126 & 5 kgs |
| Model | DR-MS-300 |
|---|---|
| Make | DR Labs |
| Display | LCD |
| Max. Volume (ml) | 2000 |
| Speed (RPM) | 1250 RPM |
| Speed Display Style | Graph (Not numeric value) |
| Top Plate Size | 135 x 135 mm |
| Plate Material | Steel |
| Max. Temp. (Plate surface) | ±1°C ( <100°C) ± 3° C (<300°C) |
| Temp. Accuracy | 0~50°C, Automatic |
| Timer | 999 Minutes |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 230 x 180 x 120 & 2.6 kgs |
| Model | DR-GMP-30 |
|---|---|
| Make | DR Labs |
| pH Range | -2.000~20.000 pH |
| Resolution | 0.001, 0.01, 0.1 pH, Selectable |
| Accuracy & Calibration Points | ±0.002 pH & up to 5 points |
| pH buffer Option | USA,(pH 1.68, 4.01, 7.00 , 10.01, 12.45) |
| NIST (pH 1.68/4.01/6.86/9.18/12.45) | |
| DIN (pH 1.09, 4.65, 6.79, 9.23, 12.75) or user defined | |
| ORP (mV) Range | 0 ̴ ±1999.9 mV |
| ORP Calibration | 1 point calibration |
| ORP Resolution & Accuracy | 0.1, 1mV Selectable & ±0.2 mV |
| ORP Measuring Mode | Absolute mV or Relative mV |
| Conductivity Range | 0 ̴ 200mS / cm |
| Resolution & Accuracy | 0.01 / 0.1 / 1 & ±0.5% F Full Scale |
| Conductivity Cell Constant | 0.01/1/10 user defined |
| Temperature Coefficient | 0.0 ̴ 10.0 % per °C |
| Conductivity Calibration Points | Up to 5 points |
| Conductivity Calibration Solution | 10uS/cm, 48uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm |
| Compensation Modes | Linear or pure water |
| TDS Range | 0 ̴ 10ppt (Max. 200ppt, Depending on factor setting |
| Resolution & Accuracy | 0.01/0.1/1 & ± 1% Full Scale |
| TDS Factor | 0.0 ̴ 1.0 |
| Salinity Range | 0 ~ 80 ppt |
| Salinity Resolution & Accuracy | 0.01/0.1/1 & ± 1% Full Scale |
| Salinity Measurement Mode | Practical Salinity (PSU) or Seawater Measurement Standard (ppt) |
| Resistivity Range | 0 ̴ 100MΩ |
| Resistivity Resolution & Accuracy | 1/0.1/0.01 & ± 1% Full size |
| Temp. Range | 0 ̴ 100 °C, /32 ̴ 212°F |
| Temp. Compensation | Automatic or Manual |
| Temp. Accuracy | ± 0.5 °C, ±0.9 °F |
| Dimensions & Weight | 210 x 188 x 60mm & 1.2kg |
| Model | DR-PH-100 |
|---|---|
| Make | DR Labs |
| pH Range | -2 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ± 0.01 pH |
| Calibration Points | up to 3 points |
| pH Buffer options | USA (pH 4.01, 7.00, 10.01) or NIST |
| ORP Range (mV) | ± 1999 mV |
| ORP Accuracy(mV) | ± 1% FS ±1 digit |
| ORP Resolution(mV) | 1 mV |
| Temp. Range | 0 to 105°C |
| Temp. Accuracy | ± 0.5°C |
| Temp. Resolution | 0.1°C |
| Temp. Compensation | 0 to 100°C, Manual/Automatic |
| Hold Function | Available |
| Auto Off function | Available |
| Electrode Connector | BNC |
| Display | Backlight LCD |
| Dimensions & Weight | 210 x 205 x 75 mm & 1.5 kg |
| Model | DR-MB-7000 |
|---|---|
| Make | DR Labs |
| Capacity | 120g |
| Moisture Range | 0~100% |
| Moisture Resolution | 0.02% ~ 0.2%(sample≥2g) |
| Moisture Accuracy | ±0.2% |
| Readability | 0.001 g (1 mg) |
| Repeatability | ±0.001 g |
| Linearity | ±0.002 g |
| Minimum Capacity | 0.01g |
| Display | Touchscreen |
| Pan Size | Ø 90 mm |
| Sensor | German Loadcell |
| Calibration | External |
| Operating Temperature | 5 to 35°C |
| Heating Source | Halogen Lamp |
| Analysis Method | Manual, Timed, Automatic |
| Temp. Sensor | PT100 |
| Temp. Setting Range | 60 to 200°C |
| Temp. Setting Resolution | 1°C |
| Time Setting | 2 to 100 mins |
| Sample Library | Yes, 100 sample methods can be stored |
| Drying Modes | Standard, Fast & Soft |
| Data Output | RS-232 & USB-A |
| No. of Storage | 100 memory |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 350 x 215 x 192 mm & 4.5 kg |
| Model | DR-MA-220 | DR-MA-320 |
|---|---|---|
| Capacity | 220g | 320g |
| Make | DR Labs | DR Labs |
| Readablity | 0.0001g (0.1mg) | 0.0001g (0.1mg) |
| Linearity | ± 0.0003g | ± 0.0003g |
| Minimum Capacity | 0.01g | 0.01g |
| Display | LCD | LCD |
| Pan Size | Ø 90 mm | Ø 90 mm |
| Response Time | 4-6 sec | 4-6 sec |
| Calibration | Internal Calibration | Internal Calibration |
| Tare Range | Full | Full |
| Operating Temperature | 15 to 30°C | 15 to 30°C |
| Operating Humidity | 50-70% R.H | 50-70% R.H |
| Warm Up time | 30 min | 30 min |
| Units | g, ct, ozt, oz, GN, dwt, lb, mg | g, ct, ozt, oz, GN, dwt, lb, mg |
| Key Sound | Yes | Yes |
| Weighing Chamber Height | 210 mm | |
| Baud Rate | 1200, 2400, 4800, 9600 | 1200, 2400, 4800, 9600 |
| Class | I | I |
| Interface | RS-232C | RS-232C |
| Date Output | Command & Continuous | Command & Continuous |
| Power Supply | AC 220V / 50 Hz | AC 220V / 50 Hz |
| Dimensions & Weight | 220 x 360 x 345 mm & 9.5 kg | 220 x 360 x 345 mm & 9.5 kg |
| Model | DR-TB-200 |
|---|---|
| Make | DR Labs |
| Turbidity Range | 0~2000 NTU, 0~500 EBC, 0~9999 ASBC |
| Resolution | 0.01 (0~99NTU) 0.1 (100~999 NTU) 1(1000~2000NTU) |
| Accuracy | ±2% of reading (0~500NTU), ±3% of reading (501~2000NTU) |
| Calibration Points | 2 to 7 points |
| Calibration Standards | 0.02, 10, 200, 500, 1000, 1500, 2000 NTU |
| TSS Range | Depends on TSS conversion factor |
| TSS Accuracy | 3% of reading |
| Light Source | Infrared-emitting diode (850nm) |
| Detector | Silicone Photodiode |
| Stray Light | < 0.02 NTU |
| Sample Vial | 60(H) x 25(dia) mm |
| Memory & Data Output | 200 data sets & USB Data output |
| Operating Temperature | 0~50°C |
| Display | 4.5″ TFT LCD |
| Power Supply | DC12V Power Adapter |
| Dimensions & Weight | 250 x 177 x 96 mm & 1.2 kg |
| Model | DR-TDS-100 |
|---|---|
| Make | DR Labs |
| Conductivity Range | 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0 mS/cm (5 auto ranges) |
| Conductivity Resolution | 0.01, 0.1, 1 |
| Conductivity Accuracy | ± 1% F.S |
| Calibration Points | up to 3 points |
| Buffer options | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Temp. Compensation | 0 to 100°C, Manual/Automatic |
| Temp. Coefficient | 0.0~10.0%/°C |
| Cell Constant | K=0.1, 1, 10 |
| Normalization Temp. | 25°C |
| TDS Range | 0~10 ppt (max. 200 ppt, depending on factor setting & ec range |
| TDS Accuracy | ± 1% F.S |
| TDS Factor | 0.1 to 1.0 (Default 0.5) |
| Temp. Range | 0 to 105°C |
| Temp. Resolution | 0.1°C |
| Temp. Accuracy | ±0.5°C |
| Hold & Auto Off function | Both Available |
| Electrode Connector | 3 pin |
| Display | Backlight LCD |
| Power | DC9V, AC220V, 50 Hz |
| Dimensions & Weight | 210 x 205 x 75 mm & 1.5 kg |
| Model | DR-IF-30 | DR-IF-50 | DR-IF-100 | DR-IF-150 |
|---|---|---|---|---|
| Make | DR Labs | DR Labs | DR Labs | DR Labs |
| Capacity of Ice Flaker | 30 kg / 24 hr | 50 kg / 24 hr | 100 kg / 24 hr | 150 kg / 24 hr |
| Storage Capacity | 10 kgs | 15 kgs | 40 kgs | 40 kgs |
| Storage Bin | ABS Plastic | ABS Plastic | ABS Plastic | ABS Plastic |
| Cooling Method | Air (inside R290A refrigerant) | Air (inside R290A refrigerant) | Air (inside R290A refrigerant) | Air (inside R290A refrigerant) |
| Ambient Temperature | Below 25°C for optimum working | Below 25°C for optimum working | Below 25°C for optimum working | Below 25°C for optimum working |
| Construction | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Noise Level | ≤52 dB | ≤52 dB | ≤52 dB | ≤52 dB |
| Water Supply | 3/4″ BSP | 3/4″ BSP | 3/4″ BSP | 3/4″ BSP |
| Refrigerant | R290A | R290A | R290A | R290A |
| Power Supply | AC 220 V / 50 Hz | AC 220 V / 50 Hz | AC 220 V / 50 Hz | AC 220 V / 50 Hz |
| Input Power | 300 W | 380 W | 520 W | 680 W |
| Dimensions | 330 x 470 x 605 mm | 400 x 540 x 700 mm | 500 x 611 x 950 mm | 500 x 611 x 950 mm |
| Gross Weight | 26 kgs | 36 kgs | 58 kgs | 60 kgs |
| Model | DR-UV-300 |
|---|---|
| Make | DR Labs |
| Optical System | Single Beam, Grating 1200 lines/mm |
| Wavelength Range | 190~1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Setting | Automatic |
| Wavelength Accuracy | ± 0.3 nm |
| Wavelength Repeatability | ± 0.1 nm |
| Cell Holder | 10mm manual 4-cell holder |
| Photometric Range | -0.3 ~ 3A, 0~200%T, 0~9999C |
| Photometric Accuracy | 0.05% T |
| Photometric Repeatability | ±0.2% T |
| Stray Light | ≤0.05%T |
| Stability | ±0.002A/h @500nm |
| Baseline Flatness | ±0.002A/h @500nm |
| Display | 128 * 64 LCD |
| Photometric Mode | T, A, C |
| Detector | Imported Japanese Silicon Photodiode |
| Light Source | Imported Japanese D2 & Tungsten Halogen Lamp |
| Output | USB Port & Parallel Port |
| Power Supply | AC 220V / 50Hz |
| Dimensions & Weight | 700 × 580 × 340 mm & 20 kgs |
| Model | DR-V-721 |
|---|---|
| Make | DR Labs |
| Optical System | CT Single Beam, Grating 1200 lines/mm |
| Wavelength Range | 320~1020 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Interval | 1 nm |
| Wavelength Accuracy | ± 2 nm |
| Wavelength Repeatability | 1 nm |
| Photometric Accuracy | ± 1% T |
| Photometric Repeatability | 0.5% T |
| Photometric Range | 0 – 1.999A, 0-199.9%T |
| Stray Light | ≤0.3%T@340nm |
| Stability | ±0.004A/h @500nm |
| Display | 4 Digit LCD |
| Photometric Mode | T, A, C |
| Detector | Silicon Photodiode |
| Light Source | Tungsten Lamp |
| Power Supply | AC 220V / 50Hz |
| Dimensions & Weight | 450 × 520 × 320 mm & 10 kgs |
| Model | DR-P-650 |
|---|---|
| Make | DR Labs |
| Frequency | 18-28 kHz Auto Tracking |
| Frequency tracking accuracy | 1 Hz real-time tracking |
| Processing Capacity | 0.5ml to 500 ml |
| Standard Probe | Ø 6 mm (1/4″) |
| Display8″ Touchscreen | 8″ Touchscreen |
| Display Function | Temperature, Power, Time, Gap Time |
| Temperature Range | 0-99°C |
| Timer | Yes upto 99 hours, 59 mins, 59 secs |
| Alarm Function | Over temperature, over current, over load, transducer abnormality, etc. |
| Operating Table | Electrically operated motorized |
| Lighting | Available inside cabinet |
| Data Memory | 9 memory group |
| Output Power | 650W (adjustable) |
| Power Source | AC 220V / 50 Hz |
| Dimensions & Weight | 280 x 280 x 490 mm – 10.2 kg |
| Model | DR-V-60 |
|---|---|
| Make | DR Labs |
| Measuring Range (mpa.s) | 20 to 20,00,000 mpa.s |
| Measurement Resolution | 0.01 mpa.s (Full Scale) |
| Speeds | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 RPM |
| No. of Speed | 8 speed settings |
| No. of Standard Spindle | 4 |
| Display | LCD |
| Auto Scan Function | Can automatically scan and recommend the preferred combination of rotor and speed |
| Temp. Monitoring | Optional – Feature available |
| Measurement Accuracy | ±1% F.S |
| Repeatability | ± 0.5% F.S |
| Output | RS 232C Interface |
| Power Supply | AC 220V / 50 Hz |
| Dimensions & Weight | 300 × 300 × 450 mm & 9 kgs |
| Model | DR-WYA-2S |
|---|---|
| Make | DR Labs |
| Measurement range refractive index nD | 1.3000 to 1.7000 |
| Measurement range refractive index Brix | 0 to 100 % Brix |
| Accuracy refractive index nD | ≤ ±0.0002 |
| Accuracy (Dissolve solids Brix) | ± ≤ 0.1% |
| Temperature Resolution | 0.1°C |
| Temperature Range (Min 0.1°C) | 0~50°C |
| Correcting range of brix versus | 15~45°C |
| Usage Temperature Range | Ambient to 35°C |
| Interface | RS232C |
| Power | AC 220V / 50 Hz |
| Dimensions & Weight | 370 x 240 x 470 mm – 12 kg |
SPECIFICATIONS:
| Model | DR-20RE | DR-30RE | DR-50RE |
|---|---|---|---|
| Rotating Speed | Color LCD Screen; 0~310rpm/min | Color LCD Screen; 0~310rpm/min | Color LCD Screen; 0~200rpm/min |
| Evap. Capacity | Max.25ml/min (H2O) | Max.27ml/min (H2O) | Max.43ml/min (H2O) |
| Temp. range/precision | Microcomputer PID controller; Water Bath | RT.-99 ºC±0.5 ºC Oil Bath RT.-210ºC±2ºC | |
| Bath Material | Integral Teflon compound heating bath with safe handle, which prevents from scald; the medium sized bath volume makes distillation fast. | ||
| Bath Size | Dia 23×13cm | Dia 26×15cm | Dia 29×17cm |
| Positive&Negative Rotating | Intermittent positive and negative rotating function with timing function (0-60s) for drying process | ||
| Lif | Automatic balance lifting which can be controlled by either button-press or Color LCD screen; the lifting length is 150mm, with fixed safety distance of 60mm, which prevents crashing. | ||
| Temp. Set | Rotating switch coding for temperature setting with big LCD screen display. | ||
| Safety | Anti-dry prevention function which makes flask automatic lifting; instrument will stop at the set timing (0-999min); automatic lifting and standby alarm protection in abnormal or over temperature state. | ||
| Heater Powe | 1.5KW | 1.5KW | 1.5KW |
| Sealing | Imported PTFE and special complex compounded with special technique, which ensures good sealing and improves the anti-corrosion and durability property. | ||
| Condenser | Vertical 3-layered coil condenser with big condensation area, equipped with drip point and backflow prevention, which effectively increases the evaporation efficiency. | ||
| Condense Area | 0.18m 2 | 0.21m2 | 0.31m 2 |
| Environment Temp | 5ºC~40 ºC | ||
Technical Specifications
| Model DR-BDDU | |
| Parameters | Values |
| Specific Conductivity | 0.8-1 μs/cm |
| Biological Activity (distillate quality) | Pyrogen Free |
| Organic Matter | Nil |
| Total Solids | 0.1 mg/ltr |
| Silica | <0.01 mg/ltr |
| Output Capacity (Approx.) | 2.5 – 4 Ltr/hr |
| Power Rating (Total) | 6 KW |
| Cooling Water Consumption (Approx.) | 150 Ltr/Hr |
| Specification | Details |
|---|---|
| Model | DR-UC-10P |
| Make | DR Labs |
| Theoretical Capacity | 10 Litre |
| Actual Water Filling | 8 Litre |
| Tank Size (mm) | 300 x 240 x 150 |
| Overall Size (mm) | 330 x 270 x 310 |
| Ultrasonic Power | 420 W |
| Heating Power | 1000 W |
| Tank, Body, Lid Material | Stainless Steel 304 |
| Time Setting | 1 to 99 mins / Always On |
| Heating Temp. | Ambient to 80°C |
| Display & Ultrasonic Frequency | LED Display, 40 kHz |
| Power Supply | 220v / 50 Hz |
| Weight | 9 kg |
Set Zero (Auto Zero) : By press push switch with audio response
Wavelength Range filters : 400 700 nm
: Built-in 9 Digital filters
Filters Wavelength : 405 nm, 430nm, 450nm, 480nm,510nm,
520nm, 546nm, 576nm, 630nm
Display Parameters : O.D., %T, Wavelenght
Battery Indicator : Graphical Indication
Detector : Silicon Photo Diode
Accuracy : + 0.01 O.D.
Stability : + 0.02 O.D. Per Hour
Light Source : Highly accurate LED source
Volume : 1 ml Minimum
Dimension : LxBxH (Approx.)
Weight : 1 kgs (Approx.)
Power : 230 V+ 10% Ac, 50 Hz
Battery Backup : 7.2 V Li-ion Re-chargeable battery
Accessories : Set of test tube 5 Nos.
Test tube holder :1 No.
| Model No. | DR-DBI |
| Display | 16×2 Alpha Numeric LCD |
| Temperature Range | Ambient to 70° C |
| Temperature Resolution | 0.1° C |
| Inbuilt timer | 0 to 99 Minute Timer |
| Android App | NA |
| Test Save Option | NA |
| Power | 220 v ±10V AC |
| Dimensions (L x B x H) | 275 x 187 x 94mm(Approx.) |
| Weight | 1.5kg Approx. |
| Accessories | Instruction Manual |
| Model No. | DR- ION-3 |
| Measurement Method | Cyanmethemoglobin Method (Optional Alkaline Hematin D Also Available on Request) |
| Display | 16×2 Alphanumeric Display |
| Wavelength | 540nm |
| Calibration | Automatic by Press CAL Key |
| Key Set Zero | Automatic by Push Switch |
| Measuring Range | 0.0 to 30.0 g/dl |
| Photo Detector | Silicon Photodiode |
| Accuracy | ±4% |
| Light Source | 540 nm Green LED |
| Frequency | 50 Hz |
| Cuvette | 12×65 mm Round Cuvette |
| Android App | Available |
| Test Report Save Option | Available/ Unlimited |
| Test Tube Holder | 01 Nos. |
| Set Of Round Cuvettes | 05 Nos. |
| Accessories | Operation Manual |
| Power | 220V ±10V AC |
| Dimension | 275 x 187 x 94 mm (Approx) |
| Weight | 0.8 Kg Approx. |
SPECIFICATIONS:
| Model | DR-OS-300 | DR-OS-30 |
|---|---|---|
| Shaking Motion | Orbital | Orbital |
| Shaking orbit | 20mm | 40mm |
| Shaking Speed Range | {01-300 RPM (400-600 RPM Optional)} | 30-200 RPM |
| Timer Range | 99h 59 min digital timer | 99h 59 min digital timer |
| Operation | Continuous/ Timer based | Continuous/ Timer based |
| Display | 6×2 Numeric LCD | 6×2 Numeric LCD |
| Max Load Capacity | 10 Kg | 10 Kg |
| Platform Size & Type | 420mm x 420mm & Universal | 12” x 12” (inches) |
| Overall dimensions | W-410 x L-530 x H-200 with Lotus Clamp | W-410 x L-530 x H-200 with Lotus Clamp |
| Power Consumption | 10 W | 10 W |
| Power Supply | 220VAC-50Hz | 220-230 V \ 50-60Hz |
| Power | 150W | 150W |
| Weight | 20 Kg | 20 Kg |
| SPECIFICATIONS | PARAMETERS | |
|---|---|---|
| Model No. | DR-VE1 | DR-VE2 |
| Dimension(LxWxH)(mm) | 185*108*125 | 153*183*159 |
| Gel size (mm) | 83*73 | 83*73 |
| Comb Specifications | 1.0mm :11 teeth 1.5mm: 11 teeth |
1.0mm: 11 teeth/ 15teeth 1.5mm: 11 teeth/ 15teeth 0.75mm: 11 teeth/15teeth |
| Maximum Buffer Capacity | 0.5L | 1.6 L |
| Number of Gels | 1-2 | 1-4 |
| SPECIFICATIONS | PARAMETERS | |
|---|---|---|
| Model No. | DR-VE1 | DR-VE2 |
| Number of Gels | 1-2 | 1-4 |
| Dimension (LxWxH)(mm) | 185*108*125 | 153*183*159 |
| Transfer size (mm) | 70*90 | 70*90mm |
| Buffer volume | 0.5L | 1.6L |
The Power Pack DR Labs is an advanced rectifier device designed to convert alternating current (AC) to direct current (DC) for high-precision applications. Its versatile design supports constant voltage and current control, making it an ideal solution for a wide range of laboratory experiments such as nucleic acid gel electrophoresis, protein gel electrophoresis, Western blotting, and protein transfer. This device is widely used in biological and medical fields for precise, stable, and reliable performance.
| Input Power Supply: | 180V-240V |
|---|---|
| AC Frequency: | 50Hz/60Hz |
| Ambient Temperature: | 4°C to 40°C |
| Environmental Humidity: | 10%-70% |
| OUTPUT RANGE: | |
| Voltage: | 6V-600V (accuracy 1V) |
| CONTROL ACCURACY: | |
| Voltage Setting: | <100V voltage stability accuracy: <1V >100V voltage stability accuracy: <±1% |
| CURRENT SETTING: | |
| CURRENT SETTING: | <100mA current stability accuracy: <1mA >100mA current stability accuracy: <±1% |
| Rated Output Power: | 300W |
| Dimensions: | 265mm (L) x 215mm (W) x 120mm (H) |
| Output Quantity: | Positive, negative A/B four groups. |
| WORKING MODES: | |
| Constant Voltage (U Mode): | Default mode, ensures constant voltage during operation. |
| Constant Current (I Mode): | Provides stable current control for sensitive applications. |
| Gradient Voltage/Current (Gradient U/I Mode): | Allows setting of three different voltage or current segments for more complex protocols. |
| Model | DR-TSI | DR-TSI-T |
|---|---|---|
| Display | 4.3 inch touch screen (capacitive type) | 4.3 inch touch screen (capacitive type) |
| Temperature control range | RT +5℃~105℃ | 0℃~105℃ |
| Temperature uniformity | ≤0.5℃ | ≤0.5℃ |
| Timer range | 1min~99h59min | 1min~99h59min |
| Temperature control accuracy | ±0.5℃(@30-50℃) | ±0.5℃(@30-50℃) |
| Display accuracy | ±0.1℃ | ±0.1℃ |
| Shaking speed | 200-3000rpm | 200~3000rpm |
| Heating time (25-100℃) | ≤15min (RT 20℃~30℃) | ≤15min (RT 20℃~30℃) |
| Refrigeration time(detected at 25℃ ambient temperature) | — | ≤20min (Ambient temperature ≤20℃: 20℃~0℃) ≤20min(Ambient temperature ≤25℃:RT~4°C) ≤20min (Ambient temperature ≤30℃:RT~10℃ |
| Heating rate gear | Max; 3℃/min; 2°C/min;1℃/min; 0.1℃/min | Max; 3℃/min; 2°C/min;1℃/min; 0.1℃/min |
| Cooling rate gear | — | Max;1℃/min;0.5℃/min;0.1℃/min |
| Program number | 50 | 50 |
| External port | USB: program related, printer; 7Pin socket: thermo lid | USB: program related, printer; 7Pin socket: thermo lid |
| Shaking amplitude | 3mm | 3mm |
| Dimension(mm) | 318x154x220 | 318×154×220 |
| Blocks | 0.5ml tubes, 2ml tubes & 96 well PCR Plate Optional: 0.2 1.5, 5, 15, 50 ml tubes, 384 well plates |
|
| Weight | 10kg | 10kg |
| Model No. | DR-UVD | DR-UVA |
| wavelength | 302 & 365nm | 365nm |
| Viewing area | 21×26 cm | |
| UV tube | 8×8 watts | |
| Two-way switch | Switches between UVA & UVB (302&365nm) | Switches between high & low intensity |
| Input power | 220 V, 50-60Hz | |
SPECIFICATIONS
| Model No. | DR-70 | DR-60 |
| Speed Range | 300 – 1200rpm | 200- 1200rpm |
| Shaking Orbit | 3mm(horizontal) | 2mm (horizontal) |
| Temp. Control Range | R.T+5°C – 70°C | R.T+5°C – 70°C |
| Temp. Setting Range | 5°C – 70°C | 5°C – 70°C |
| Temp. Stability | @37°C ±0.2°C | ±0.2°C |
SPECIFICATIONS
| Model No. | DR-20HE | DR-25HE |
| Gel dimension | 20×20 cm & 20×25 cm | 25×25 cm & 33×25 cm |
| Sample combs | 4(1.5, 1.5) & 4 (1mm) | 4(1.5) & 4 (1mm) |
| Comb thickness | 1.5 mm, 1mm | 1.5mm & 1mm |
| Buffer volume | 2.5 L | 4L |
| Max. no. sample | 60 | 104 |
| Size (LxWxH) | 43×23.5×7.5 | 53x28x8.5 |
| MODEL | DR-EW |
|---|---|
| Wash manifolds | 8-and 12-channel |
| Microplates | 96-well and 48-well plate |
| Wash lines | 1-12 line adjusting |
| Washing times | 1-99 times adjustable |
| Soaking or shaking | Soaking:0-999s adjustable; shaking:999s adjustable |
| Solution channel | 3 pc |
| Water mist catching device | No |
| Auto discharge for waste liquid | No |
| Washing programs | 100 washing programs |
| Models | DR-FD-10 | DR-FD-10L | DR-FD-10LZ | DR-FD-10LZ+ |
|---|---|---|---|---|
| Type | Standard chamber | Standard Chamber with 8 manifolds | TOP Press | TOP Press with standard chamber |
| Freeze drying area | 0.12 ㎡ | |||
| Ice Condenser capacity | 3-4 kg /24h | |||
| Condenser temperature | -50°C /-80°C | |||
| Final Vacuum | < 10 Pa | |||
| Tray | Ф200 mm,4 layers, Spacing 70 mm | |||
| Bulk capacity | 1.2 L, 10 mm thickness | |||
| Vial capacity Φ12mm | 820 pcs | |||
| Vial capacity Φ16mm | 460 pcs | |||
| Vial capacity Φ22mm | 244 pcs | |||
| Condenser size | Ф215 mm, 140 mm deep | |||
| Drying chamber size | Ф260 × 430 mm | |||
| Vacuum Pump Flow Rate | 2 L/S, 7.2 m³/h | |||
| Defrosting | Electric Defrosting | |||
| Cooling | Air cooling, ambient temperature ≤28°C | |||
| Voltage | 220V /50 Hz, single phase | |||
| Power | 970 W (-50°C) /1400 W (-80°C) | |||
| Dimension | 610 x 450 x (370+430) mm (-50°C) 850 x 680 x (400+430) mm (-80°C) | |||
| Weight | 70 kg (-50°C) 130 kg (-80°C) | |||
| Pixel Resolution: | 6.3 million pixels (3072 x 2048) |
| Pixel Size: | 2.4 x 2.4 μm |
| Exposure Time: | 17 μs – 15 s |
| Focal Length: | 8-48mm |
| Grayscale: | 16-bit (256 levels) |
| Field of View: | 220 x 220 mm |
| Operating System: | Windows OS, 10.4-inch display (1024 x 768 resolution) |
| External Interfaces: | USB 3.0 x 2 |
| Operating Voltage: | 100V-240V |
| Power Consumption: | 200W |
| Net Weight: | 27kg |
| 1D Image analysis: | 1D image analysis and capture software. |
| ax. Speed | 18500rpm |
| Max. RCF | 23990×g |
| Max. Capacity | 4×250ml |
| Time Range | 0~99min |
| RPM/RCF Convert | Yes |
| Noise (dB) | ≤ 55 |
| Temperature | / |
| Acc/Dec | 10 Kinds |
| Speed Accuracy | ±20r/min |
| Temperature Accuracy | / |
| Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
| Certificates | CE,ISO & Calibration report are available |
| Size (W x D x Hmm) | 400×570×320mm |
| Net Weight(Kg) | 40KG |
| NO | Rotor | Max Speed (rpm) | Max Volume (ml) | Max. RCF(×g |
|---|---|---|---|---|
| 1 | Swing Rotor(Round bucket) | 4000 | 4x250ml | 2880 |
| 2 | Swing Rotor(Square bucket) | 4000 | 4x250ml | 2830 |
| 3 | Swing Rotor | 4000 | 4x16x7ml | 2860 |
| 4 | Swing Rotor | 4000 | 4x16x5ml | 2470 |
| 5 | Swing Rotor | 4000 | 4x13x10ml | 2830 |
| 6 | Microplate rotor(box type) | 4000 | 2×3×96 well | 2310 |
| 7 | Microplate rotor(fame type) | 4000 | 2×3×96 well | 2270 |
| 8 | Swing out rotor | 5000 | 4×1×50ml | 4730 |
| 9 | Swing out rotor | 5000 | 4×1×100ml | 4730 |
| 10 | Swing out rotor | 4000 | 4×2×100ml | 3020 |
| 11 | Swing out rotor | 4000 | 4×2×50ml | 3020 |
| 12 | Swing out rotor | 4000 | 4×4×15ml | 3020 |
| 14 | Swing out rotor | 4000 | 4×6×15ml | 3200 |
| 15 | Swing out rotor | 4000 | 4×4×10/7ml | 2770 |
| 16 | Swing out rotor | 4000 | 4×4×10/7ml | 2770 |
| 17 | Swing out rotor | 4000 | 4×4×5ml adapter | 2360 |
| 18 | Swing out rotor | 4000 | 4×6×10/7ml | 2770 |
| 19 | Swing out rotor | 4000 | 4×6×5ml adapter | 2360 |
| 20 | Swing out rotor | 4000 | 4×8×10/7ml | 2770 |
| 21 | Swing out rotor | 4000 | 4×8×5ml adapter | 2360 |
| 22 | Swing out rotor | 4000 | 4×12×5ml | 2480 |
| 23 | Swing out rotor | 4000 | 4×12×7ml | 2760 |
| 24 | Swing out rotor | 4000 | 4×10×10ml | 2880 |
| 25 | Fixed Rotor | 14000 | 4×8PCR | 12070 |
| 26 | Fixed Rotor | 13000 | 6×8PCR | 16080 |
| 27 | Fixed Rotor | 14000 | 8×8PCR | 13390 |
| 28 | Fixed Rotor | 13000 | 12×8PCR | 17220 |
| 29 | Fixed Rotor | 14000 | 40×0.5ml | 19960 |
| 18B-33 | Fixed Rotor | 18500 | 12×1.5ml | 23990 |